Late proximal pulmonary artery occlusion in a child with a single chamber after a right-sided Blalock-Taussig shunt

نویسندگان

  • Tomasz Nałęcz
  • Bartłomiej Mroziński
  • Tomasz Moszura
  • Michał Wojtalik
چکیده

The paper presents the management of a child born with pulmonary valve atresia, a single (double-inlet) ventricle, right ventricular hypoplasia, and perimembranous septal defect. The first stage of treatment consisted in a Blalock-Taussig shunt. Control angiography performed 1 year after surgery confirmed that the anastomosis was correct, and there was no narrowing at the connection. The first stage of treatment was complicated by the occlusion of the left pulmonary artery, as diagnosed during cardiac catheterization before the planned bidirectional Glenn anastomosis. A decision was made to perform surgery through a left thoracotomy without a cardiopulmonary bypass in order to restore the continuity of the left pulmonary artery.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Recanalisation of an occluded modified Blalock-Taussig shunt by balloon dilatation.

A four year old boy with pulmonary atresia and ventricular septal defect had an acute cyanotic episode three years after undergoing a right-sided, 6 mm diameter, modified Blalock-Taussig shunt. On admission no continuous murmur could be heard from the shunt and the typical high velocity, continuous flow profile of the shunt could not be identified by Doppler echocardiography. At catheterisation...

متن کامل

Transcatheter occlusion of a Blalock-Taussig shunt with a detachable balloon in a child.

A case of transcatheter occlusion of a Blalock-Taussig shunt with a detachable silicone filled balloon is described. This 11 year old boy had previously had a repair of tetralogy of Fallot together with ligation of a large Blalock-Taussig shunt. Though there was a good surgical result, the shunt proved to be incompletely closed leaving a significant left to right shunt. As an alternative to a f...

متن کامل

Modified Blalock-taussig Shunt ----in- Hospital Shunt Occlusion: Experience at Nicvd

A modified Blalock-Taussig shunt (mBTS) is a surgically placed graft between the systemic and pulmonary arterial circulations that redirects systemic blood flow into the pulmonary circulation. It is often placed in those with rightsided obstructive cardiac defects to increase pulmonary blood flow. Postoperative shunt patency is critical to adequate systemic oxygenation. Nevertheless, in the imm...

متن کامل

A novel use of an Amplatzer septal occluder.

A 4 year old girl with an underlying diagnosis of atrioventricular discordance, double outlet right ventricle with pulmonary valvar atresia, and subpulmonary ventricular septal defect, was admitted for elective surgery. She had had surgery as a neonate to insert a right 5 mm Gore-tex modified Blalock Taussig shunt, and again at 3 years old for formation of a bidirectional Glenn anastomosis. Car...

متن کامل

Impact of 3-mm Blalock-Taussig shunt in neonates and infants with a functionally single ventricle.

Functionally single ventricle (f-SV) is susceptible to volume overload. Atrioventricular valve regurgitation (AVVR) tends to develop and ventricular function deteriorates due to excessive pulmonary blood flow following modified Blalock-Taussig shunt (mBTS). On the other hand, a small caliber graft has risks of early obstruction and poor growth of pulmonary vascular beds. We assessed the effect ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 13  شماره 

صفحات  -

تاریخ انتشار 2016