Comparison of body fluid distribution between chronic haemodialysis and peritoneal dialysis patients as assessed by biophysical and biochemical methods.
نویسندگان
چکیده
BACKGROUND The control of extracellular volume is a key parameter for reducing hypertension and the incidence of cardiovascular mortality in dialysis patients. In recent years bioimpedance measurement (BIA) has been proven as a non-invasive and accurate method for measuring intracellular and extracellular fluid spaces in man. In addition, plasma atrial natriuretic peptide (ANP) and cyclic guanosine monophosphatase (cGMP) concentrations have been shown to reflect central venous filling. Using these methods, we compared body fluid status between stable patients on haemodialysis and peritoneal dialysis. METHODS Thirty-nine chronic haemodialysis patients, 43 chronic peritoneal dialysis patients and 22 healthy controls were included in the study. Multifrequency BIA was performed using the Xitron BIS4000B device (frequencies from 5 to 500 kHz were scanned and fitted) in patients before and after haemodialysis. Peritoneal dialysis patients were measured after drainage of the dialysate. Plasma ANP and cGMP levels were measured in plasma using a (125)I solid phase RIA. Serum albumin concentrations and serum osmolality were measured in all patients. The body fluid data were analysed in relation with the clinical findings. RESULTS Total body water (TBW) was 0.471+/-0.066 l/kg before haemodialysis and 0.466+/-0.054 l/kg after haemodialysis. Peritoneal dialysis patients had a TBW (0.498+/-0.063 l/kg) that was greater than the before and after dialysis values of haemodialysis patients. The extracellular body fluid (V(ecf)) was increased pre-haemodialysis. It was even greater in peritoneal dialysis patients compared with patients both pre- and post-haemodialysis (pre 0.276+/-0.037 l/kg; post 0.254+/-0.034 l/kg; peritoneal dialysis 0.293+/-0.042 l/kg, P<0.05). However, plasma ANP concentrations (representing intravascular filling) in peritoneal dialysis patients were comparable with post-haemodialysis values (284+/-191 pg/ml vs 286+/-144 pg/ml). The correlation coefficient between sysRR and V(ecf) was r=0.257 in haemodialysis (P=0.057) and r=0.258 in peritoneal dialysis (P<0.05). A significant negative correlation was found between serum albumin and V(ecf)/TBW in peritoneal dialysis patients (r= -0.624). CONCLUSION Body fluid analysis by BIA demonstrated that TBW and V(ecf) were increased in peritoneal dialysis patients, and were comparable or even greater than values found before haemodialysis. However, plasma ANP levels indicated that intravascular filling was not increased in peritoneal dialysis. The ratio of V(ecf) to TBW was correlated to systolic pressure and negatively to serum albumin in peritoneal dialysis patients.
منابع مشابه
Chronic renal failure and sexual functioning: clinical status versus objectively assessed sexual response.
BACKGROUND Sexual dysfunctions are common among patients with chronic renal failure. The prevalence was assessed in a population of 281 patients (20-60 years), and it was attempted to determine whether their mode of treatment (haemodialysis, peritoneal dialysis, or kidney transplantation), or biochemical and endocrine variables and neuropathy affect sexual functioning. Patients with rheumatoid ...
متن کاملCorrelational studies on insulin resistance and leptin gene polymorphisms in peritoneal dialysis patients
Objective(s):The aim of the study was to investigate the relationship between insulin resistance (IR) and leptin (LEP) gene polymorphisms in peritoneal dialysis (PD) patients. Materials and Methods: From July 1, 2011 to August 1, 2011, patients who received chronic PD were chosen and divided into three groups (DM, high HOMR-IR, and low HOMR-IR). Two PCR products of LEP were sequenced and aligne...
متن کاملبررسی عوارض دیالیز صفاقی مستمر و عوامل دخیل در آن در 57 بیمار مبتلا به نارسایی کلیه
Background and purpose: Recognition of some predictive biomarkers can improve management of the patient treated by dialysis. This study was designed to recognize and assess relationship between some hematologic and biochemical markers with morbidity in patient treated with peritoneal dialysis. Materials and methods: Ïn this longitudinal study we enrolled 57 patient with end stage renal dis...
متن کاملComparison of the Effects of Dialysis Methods (Haemodialysis vs Peritoneal Dialysis) on Diastolic Left Ventricular Function Dialysis Methods and Diastolic Function
INTRODUCTION In patients undergoing chronic dialysis, several factors appear to influence the occurrence of cardiac abnormalities. The aim of our study was to evaluate the effects of two different methods of renal replacement therapy (chronic haemodialysis (HD) and continuous ambulatory peritoneal dialysis (CAPD)) on left ventricular (LV) diastolic function. PATIENTS AND METHODS We enrolled 6...
متن کاملخصوصیات اپیدمیولوژیک و جمعیتشناسی بیماران همودیالیزی و دیالیز صفاقی
Normal 0 false false false EN-US X-NONE AR-SA MicrosoftInternetExplorer4 /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal" mso-tstyle-rowband-size:0 mso-tstyle-colband-size:0 mso-style-noshow:yes mso-style-priority:99 mso-style-qformat:yes m...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association
دوره 16 12 شماره
صفحات -
تاریخ انتشار 2001