Pulse transit time and blood pressure during cardiopulmonary exercise tests.
نویسندگان
چکیده
Pulse transit time (PTT), the interval between ventricular electrical activity and peripheral pulse wave, is assumed to be a surrogate marker for blood pressure (BP) changes. The objective of this study was to analyze PTT and its relation to BP during cardiopulmonary exercise tests (CPET). In 20 patients (mean age 51+/-18.4 years), ECG and finger-photoplethysmography were continuously recorded during routine CPETs. PTT was calculated for each R-wave in the ECG and the steepest slope of the corresponding upstroke in the plethysmogram. For each subject, linear and non-linear regression models were used to assess the relation between PTT and upper-arm oscillometric BP in 9 predefined measuring points including measurements at rest, during exercise and during recovery. Mean systolic BP (sBP) and PTT at rest were 128 mm Hg and 366 ms respectively, 197 mm Hg and 289 ms under maximum exercise, and 128 mm Hg and 371 ms during recovery. Linear regression showed a significant, strong negative correlation between PTT and sBP. The correlation between PTT and diastolic BP was rather weak. Bland-Altman plots of sBP values estimated by the regression functions revealed slightly better limits of agreements for the non-linear model (-10.9 to 10.9 mm Hg) than for the linear model (-13.2 to 13.1 mm Hg). These results indicate that PTT is a good potential surrogate measure for sBP during exercise and could easily be implemented in CPET as an additional parameter of cardiovascular reactivity. A non-linear approach might be more effective in estimating BP than linear regression.
منابع مشابه
Designing and Constructing an Optical System to measure Continuous and Cuffless Blood Pressure Using Two Pulse Signals
Introduction Blood pressure (BP) is one of the important vital signs that need to be monitored for personal healthcare. Arterial blood pressure is estimated from pulse transit time (PTT). This study uses two pulse sensors to get PTT. The aim of this study was to construct an optical system and to monitor blood pressure continuously and without cuff in people with different ages. Materials and M...
متن کاملAn evaluation of the cuffless blood pressure estimation based on pulse transit time technique: a half year study on normotensive subjects.
In the present study, we investigated the relationship between blood pressure (BP) and pulse transit time (PTT) and evaluated the accuracy of the PTT-based cuffless BP estimation on 14 normotensive subjects. Least-squares regression was used to estimate BP in the first test and a repeatability test carried out half year later. BP in the repeatability test was also estimated using the regression...
متن کاملGas exchange detection of exercise-induced right-to-left shunt in patients with primary pulmonary hypertension.
BACKGROUND Because of high pulmonary vascular resistance in patients with primary pulmonary hypertension (PPH), right atrial pressure may exceed left atrial pressure during exercise, resulting in a right-to-left shunt via a patent foramen ovale (PFO). This shunting would disturb arterial PCO2 and H+ homeostasis if the pulmonary blood were not simultaneously hyperventilated to compensate for the...
متن کاملCan pulse transit time be useful for detecting hypertension in patients in a sleep unit?
INTRODUCTION Pulse transit time (PTT) is the time that a pulse wave takes to travel between two different arterial points, and may be useful in estimating blood pressure. This noninvasive technique, which does not add any cost to the procedure, offers the advantage of avoiding 'arousals' during sleep measurement as occurs with ambulatory blood pressure monitoring (ABPM). We aim to confirm the u...
متن کاملUse of pulse transit time as a measure of inspiratory effort in patients with obstructive sleep apnoea.
Pulse transit time (PTT) is the time taken for the arterial pulse pressure wave to travel from the aortic valve to a peripheral site. For convenience, it is usually measured from the R wave on the electrocardiogram to the pulse wave arrival at the finger. Pulse transit time is inversely proportional to blood pressure, and the falls in blood pressure which occur with inspiration (pulsus paradoxu...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Physiological research
دوره 63 3 شماره
صفحات -
تاریخ انتشار 2014