Analysis of 19 preservatives in Polyvinyl Alcohol Cooling Towels Used in Japan by High Performance Liquid Chromatography with Photo Diode Array Detector
نویسندگان
چکیده
The cases of contact dermatitis due to using polyvinyl alcohol (PVA) towel containing isothiazolinone preservatives have been reported in Japan and we had investigated the concentrations of isothiazolinones and the removal of these preservatives from PVA towels by washing before initial use in the previous study conducted from 2011 to 2012. However, the clinical information regarding contact dermatitis due to using PVA cooling towels containing other preservatives was provided from the supplier of PVA towel in the summer of 2013. Thus, we analyzed 19 preservatives in 21 PVA towels by high performance liquid chromatography with photo diode array detector in this study. A good separation of these preservatives was observed using InertSustain® Phenyl column and 0.1 % formic acid solution as the mobile phase. 2-Methyl-4-isothiazolin-3-one and 5-chloro-2-methyl-4isothiazolin-3-one were detected in 16 samples, including the sample which was sold in a dry condition; the concentrations of these substances ranged from 7.9-84 μg/g-wet and 9.5-173 μg/g-wet, respectively (2.9 μg/g-dry and 9.3 μg/g-dry, respectively). 2-n-Octyl-4-isothiazolin-3-one was detected in one sample (484 μg/g-wet). 2Bromo-2-nitropropane-1,3-diol (BP) was detected in 15 samples, including the sample which was sold in a dry condition; its concentration ranged from 68-2303 μg/g-wet (160 μg/g-dry). 2-Phenoxyethanol (PE) and benzoic acid (BA) were detected in 3 and 2 samples, and their concentrations ranged from 99-3171 μg/g-wet and 1896-23043 μg/g-wet. Other preservatives were not detected. Although isothiazolinone preservatives were detected in 17 samples, the product notes of 10 products, including the product with clinical information, did not describe about the use of isothiazolinone preservatives. Since PVA cooling towels in contact with human skin for a long time, the PVA cooling towels should be used with caution, especially on patients who are already sensitive to isothiazolinone preservatives. Furthermore, we evaluated the effectiveness of the washing process on the removal of BP, PE, and BA from the PVA towels before their initial use. The results of this laboratory-simulated washing procedure suggest that contact dermatitis is likely not related to the presence of BP, PE, and BA in washed PVA towels.
منابع مشابه
Fine quantitation of novel trace taxans in suspension-cultured Corylus avellana L. cells by photo diode array HPLC technique.
Taxanes are widely known as great family of antitumor compounds. Identification of certain taxanes, particularly taxol, has opened new perspectives for further researches in plant and medical sciences. The aim of the present study was to manipulate chromatographic method in order to detect and quantified novel trace taxanes in suspension-cultured hazel (Corylus avellana L.) cells. A rapid growi...
متن کاملDetermination of Potassium Sorbate and Sodium Benzoate in "Doogh" by HPLC and Comparison with Spectrophotometry
There are various methods for the analysis of Potassium Sorbate and Sodium Benzoate in food products, but a rapid and reliable method for identification of these preservatives in Doogh (an Iranian traditional dairy drink) is a procedure, in which high performance liquid chromatography (HPLC) utilized and followed by UV diode array detection of the two preservatives. The aim of this case study w...
متن کاملDetermination of Potassium Sorbate and Sodium Benzoate in "Doogh" by HPLC and Comparison with Spectrophotometry
There are various methods for the analysis of Potassium Sorbate and Sodium Benzoate in food products, but a rapid and reliable method for identification of these preservatives in Doogh (an Iranian traditional dairy drink) is a procedure, in which high performance liquid chromatography (HPLC) utilized and followed by UV diode array detection of the two preservatives. The aim of this case study w...
متن کاملمروری بر انواع آشکارسازهای اتصالی در سیستمهای کروماتوگرافی مایع برای تشخیص و اندازهگیری مواد منفجره
Abstract high-performance liquid chromatography (HPLC) are including systems used for separation of explosive mixtures that despite the advantages of rapid analysis, low sample volume, and low consumption organic solvent, in use for complex matrices need to improve the selectivity and sensitivity stationary phase. One of the methods to improve selectivity and sensitivity is choosing the appr...
متن کاملOptimization of a Dispersive Liquid-Liquid Microextration Method for Analysis of Chlorpyrifos in Urine Using the Chemometrics Method
Aims: The use of simple, low cost, high -efficiency extraction methods for sample preparation in the forensic toxicology has been considered. Nowadays, the chemometrics technique can be used to determine the influencing factors on the response to optimize extraction methods. The aim of this study was to design and optimize a dispersive liquid-liquid microextraction (DLLME) method for extraction...
متن کامل