Accident or arson: is CO-oximetry reliable for carboxyhemoglobin measurement postmortem?

نویسندگان

  • Kalen N Olson
  • Melissa A Hillyer
  • Julie S Kloss
  • Roberta J Geiselhart
  • Fred S Apple
چکیده

A 46-year-old woman was found dead in the basement of her home after a fire. External examination of the body showed a wound to the head and soot in the nose and mouth, with soot also found internally in the trachea and bronchi upon autopsy. On questioning by the police, the woman’s husband admitted that he and his wife were having an argument that led to him accidentally knocking her unconscious by pushing her and causing her head to strike an object. The husband, believing her dead, then set fire to the house to hide his wife’s death. Police charged the husband with first-degree intentional felony murder (intentionally causing death while committing or attempting to commit arson) and second-degree unintentional felony murder (unintentionally causing death while committing a felony). The prosecuting lawyers’ case hinged on the measured carboxyhemoglobin (COHb) concentration to prove that the wife was indeed alive when the fire was started and therefore the husband was also guilty of murder by committing arson. The blood COHb concentration measured by a 6-wavelength CO-oximeter was 61.4%. Defense lawyers argued that CO-oximetry was an unreliable method for postmortem COHb measurement, compared with other methods, and therefore the result obtained was not valid proof “beyond a reasonable doubt” that arson was the cause of the wife’s death.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Postmortem CO - oximetry

The focus of this article is the application of CO-oximetry in the analysis of blood samples after death. This is largely confined to confirming or excluding carbon monoxide poisoning as a contributory or prime cause of death, by measurement of COHb. Issues addressed will include: the toxicity of carbon monoxide; the causes of lethal carbon monoxide poisoning; and the particular difficulties su...

متن کامل

Accuracy of noninvasive multiwave pulse oximetry compared with carboxyhemoglobin from blood gas analysis in unselected emergency department patients.

STUDY OBJECTIVE Accurate and timely diagnosis of carbon monoxide (CO) poisoning is difficult because of nonspecific symptoms. Multiwave pulse oximetry might facilitate the screening for occult poisoning by noninvasive measurement of carboxyhemoglobin (COHb), but its reliability is still unknown. We assess bias and precision of COHb oximetry compared with the criterion standard blood gas analysi...

متن کامل

A new tool for the early diagnosis of carbon monoxide intoxication.

Invasive measurement of carboxyhemoglobin (COHb) by blood gas analysis (BGA) is accepted as the standard diagnostic procedure in diagnosis of inhalation injury and carbon monoxide (CO) intoxications. The main disadvantage of BGA with COHb testing is the unavailability in pre-hospital rescue conditions. The non-invasive SpCO analysis using pulse CO oximetry (Rad57, Masimo Corp., USA) represents ...

متن کامل

Endogenous carbon monoxide production in extracorporeal membrane oxygenation‐related hemolysis: potential use of point‐of‐care CO‐oximetry carboxyhemoglobin to detect hemolysis

Extracorporeal membrane oxygenation (ECMO)-related hemolysis is a rare but devastating condition. Death is inevitable without early recognition and prompt management. Endogenous carbon monoxide production, as an epiphenomenon of hemolysis, potentially allows rapid detection of such condition by use of point-of-care CO-oximetry carboxyhemoglobin.

متن کامل

Non-invasive carboxyhemoglobin monitoring: screening emergency medical services patients for carbon monoxide exposure.

INTRODUCTION Carbon monoxide (CO) toxicity is a significant health problem. The use of non-invasive pulse CO-oximetry screening in the emergency department has demonstrated that the rapid screening of numerous individuals for CO toxicity is simple and capable of identifying occult cases of CO toxicity. OBJECTIVE The objective of this study was to extend the use of this handheld device to the ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 56 4  شماره 

صفحات  -

تاریخ انتشار 2010