Non-Contact Detection of Breathing Using a Microwave Sensor

نویسندگان

  • Devis Dei
  • Gilberto Grazzini
  • Guido Luzi
  • Massimiliano Pieraccini
  • Carlo Atzeni
  • Sergio Boncinelli
  • Gianna Camiciottoli
  • Walter Castellani
  • Massimo Marsili
  • Juri Lo Dico
چکیده

In this paper the use of a continuous-wave microwave sensor as a non-contact tool for quantitative measurement of respiratory tidal volume has been evaluated by experimentation in seventeen healthy volunteers. The sensor working principle is reported and several causes that can affect its response are analyzed. A suitable data processing has been devised able to reject the majority of breath measurements taken under non suitable conditions. Furthermore, a relationship between microwave sensor measurements and volume inspired and expired at quiet breathing (tidal volume) has been found.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Detection of napropamide by microwave resonator sensor using carbon nanotube – polypyrrole- chitosan layer

This paper presents the design and fabrication of proximity coupled feed disk resonator coated with Multi Walled Carbon Nanotubes (MWCNTs) and Polypyrrole-Chitosan (PPy-CHI) layers as a napropamide sensor. Computer Simulation Technology (CST) microwave studio was used to obtain the best design of disk resonator and feed line position in 5 GHz resonant frequency. Also, MWCNTs - PPy-CHI layers we...

متن کامل

Feasibility Study for Non-Contact Heartbeat Detection at 2.4 GHz and 60 GHz

Two new schemes for human non-invasive cardiopulmonary activity monitoring are demonstrated using microwave low power and non-contact Doppler sensors. The two systems, using direct conversion architecture and simple design, are demonstrated and tested at a distance of 1 m from the patient. The first one proposes a simple technique for direct measurement of heartbeat signal at 2.4 GHz while the ...

متن کامل

Movement Detection in Non-los Environment Using Microwave

Microwave can be used as a source to detect any movement behind the barrier and it paves way for many unknown intrusion similar to the movement detection in Line of Sight (LOS) environment by passive infrared sensors. Microwave frequencies can penetrate the barrier to gather information in non LOS environment. However the insight about the situation of a person behind the opaque medium will al...

متن کامل

Non-contact breath sensor based on a Doppler detector

Respiratory activity is an important parameter for observation of human body activity. A normal adult has a respiratory rate of 12–15 breaths/min in normal conditions. Breath sensor based on non-contact Doppler detector allows for the measurement and detection and the absence of the breathing action, which may cause death in a few minutes. The monitoring and detection of some respiratory abnorm...

متن کامل

Microwave Doppler Transducer for Contactless Cardiorespiratory Monitoring

One presents the results of a study concerning the use of microwave Doppler transducer for contact-less detection of cardiorespiratory activity. The main element of the installation is a microwave Doppler transducer. The Doppler signal resulting from the movement of the anatomical structures is a complex one. The experimental setup also includes an electrocardiograph, a photopletismograph and a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2009