Performance Characteristics of a New Flexible Nitinol 19-Gauge Endoscopic Ultrasound-Guided Fine Needle Aspiration Needle

نویسندگان

  • Disaya Chavalitdhamrong
  • Peter V. Draganov
چکیده

We would like to report out results with the use of new flexible nitinol 19 gauge (G) endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) needle. We studied the performance characteristics of this new EUS needle (ExpectTM 19 Flex; Boston Scientific, Natick, MA, USA) in cases considered difficult to perform with traditional stainless steel 19 G needles. Inclusion criteria were 1) lesion in the pancreatic head, 2) nondiagnostic prior EUS-FNA, 3) subepithelial lesion in proximal stomach, and 4) passage of 0.035” wire needed to facilitate EUS-guided therapeutic procedure. Ten EUS procedures were done in 10 patients. We experienced technical success in all patients (100%). Adequate for cytologic evaluation specimen was obtained by mean of 1.2 (range, 1 to 2) passes in all eight patients (100%: six pancreatic head mass, one prior nondiagnostic EUS-FNA, and one gastric subepithelial lesion). One pseudocyst drainage and one pancreatic duct drainage were both successful. In one patient we were unable to achieve the final diagnosis despite the adequate specimen for evaluation by our cytologist. Of the seven cases in which final tissue diagnosis was achieved, FNA established the diagnosis in five (71%), and the remaining two required surgical biopsy. For all patients, the diagnostic yield of FNA was five out of eight (63%). Performance characteristics needle scores (1, best; 3, same; 5, worst compare with stainless steel 19 G needle) were passability through the scope 1.67±0.5, sharpness 1.55±0.53, visualization 2.22±0.44, durability 2.33±0.71, connection to the scope 2.44±0.73, ergonomics

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Endoscopic Ultrasound Guided Rendezvous Drainage of Biliary Obstruction Using a New Flexible 19-Gauge Fine Needle Aspiration Needle

Background and Aim. A successful endoscopic ultrasound guided rendezvous (EUS-RV) biliary drainage is dependent on accurate puncture of the bile duct and precise guide wire manipulation across the ampulla of Vater. We aim to study the feasibility of using a flexible 19-gauge fine aspiration needle in the performance of EUS-RV biliary drainage. Method. This is a retrospective case series of EUS-...

متن کامل

Procore and Flexible 19 Gauge Needle Can Replace Trucut Biopsy Needle?

Endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) is routinely performed for establishing tissue diagnosis in patients with gastrointestinal tumors. The concept of delivering chemotherapy based on molecular markers and the ability to establish a reliable diagnosis in lieu of an onsite cytopathologist has fuelled the recent trend in procuring core tissue by means of EUS-guided fine n...

متن کامل

Henry Lik – Yuen Chan

1. Wiersema MJ, Hawes RH, Tao LC, et al. Endoscopic ultrasonography as an adjunct to fine needle aspiration cytology of the upper and lower gastrointestinal tract. Gastrointest Endosc 1992;38: 35–39. 2. Gress F, Gottlieb K, Sherman S, et al. Endoscopic ultrasonography-guided fine-needle aspiration biopsy of suspected pancreatic cancer. Ann Intern Med 2001;134:459–464. 3. Lee JH, Stewart J, Ross...

متن کامل

Randomized Trial Comparing the Flexible 19G and 25G Needles for Endoscopic Ultrasound-Guided Fine Needle Aspiration of Solid Pancreatic Mass Lesions

OBJECTIVES Although a large gauge needle can procure more tissue at endoscopic ultrasound-guided fine needle aspiration (EUS-FNA), its advantage over smaller needles is unclear. This study compared flexible 19G and 25G needles for EUS-FNA of solid pancreatic masses. METHODS This was a randomized trial of patients undergoing EUS-FNA of pancreatic masses using flexible 19G or 25G needle. Main o...

متن کامل

High-Quality Endoscopic Ultrasound-Guided Fine Needle Aspiration Tissue Acquisition

Endoscopic ultrasound-guided fine needle aspiration is a multistep procedure that involves proper clinical indication, correct selection of needles, adapting evidence-based techniques such as the fanning maneuver and not routinely using suction or the stylet for tissue sampling, and establishing reliable cytopathology support. Integrating cytopathology in the training curriculum and developing ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2013