penMesh - Monte Carlo Radiation Transport Simulation in a Triangle Mesh Geometry
نویسندگان
چکیده
We have developed a general-purpose Monte Carlo simulation code, called penMesh, that combines the accuracy of the radiation transport physics subroutines from PENELOPE and the flexibility of a geometry based on triangle meshes. While the geometric models implemented in most general-purpose codes--such as PENELOPE's quadric geometry--impose some limitations in the shape of the objects that can be simulated, triangle meshes can be used to describe any free-form (arbitrary) object. Triangle meshes are extensively used in computer-aided design and computer graphics. We took advantage of the sophisticated tools already developed in these fields, such as an octree structure and an efficient ray-triangle intersection algorithm, to significantly accelerate the triangle mesh ray-tracing. A detailed description of the new simulation code and its ray-tracing algorithm is provided in this paper. Furthermore, we show how it can be readily used in medical imaging applications thanks to the detailed anatomical phantoms already available. In particular, we present a whole body radiography simulation using a triangulated version of the anthropomorphic NCAT phantom. An example simulation of scatter fraction measurements using a standardized abdomen and lumbar spine phantom, and a benchmark of the triangle mesh and quadric geometries in the ray-tracing of a mathematical breast model, are also presented to show some of the capabilities of penMesh.
منابع مشابه
Comparison of MCNP4C, 4B and 4A Monte Carlo codes when calculating electron therapy depth doses
ABSTRACT Background: accurate methods of radiation therapy dose calculation. There are different Monte Carlo codesfor simulation of photons, electrons and the coupled transport of electrons and photons. MCNPis a general purpose Monte Carlo code that can be used for electron, photon and coupledphoton-electron transport.Monte Carlo simulation of radiation transport is considered to be one of the ...
متن کاملComparison of I-131, I-123 Absorbed Dose and Tc-99m in Thyroid Scanning Using MCNP Code in ORNL-MIRD Phantom
Introduction: Thyroid cancer is at the ninth from ten of common malignant cancer. A man has higher risk to get Thyroid cancer that a woman has. This organ is lain near human neck. The use of radioactive I-131, I-123 and Tc-99m for diagnosis of thyroid cancer has a risk where other organs around Thyroid will accept dose of radiation. One of the risks is large dose which is accep...
متن کاملInvestigation and Comparison of Metal Nanoparticles on Dose Enhancement Effect in Radiotherapy Using Monte Carlo Simulation Method
Introduction: The main goal of radiation therapy is destroying the tumor so that the surrounded healthy tissues have received the least amount of radiation at the same time. In recent years, the use of nanoparticles has received much attention due to the increasing effects they can have on the deposited dose into the cancer cells. The aim of this study was to investigate the effects of nanopart...
متن کاملAn assessment of the Photon Contamination due to Bremsstrahlung Radiation in the Electron Beams of a NEPTUN 10PC Linac using a Monte Carlo Method
Introduction: In clinical electron beams, most of bremsstrahlung radiation is produced by various linac head structures. This bremsstrahlung radiation dose is influenced by the geometry and construction of every component of the linac treatment head structures. Thus, it can be expected that the amount of the contaminated photon dose due to bremsstrahlung radiation varies among different linacs,...
متن کاملCT-Based Brachytherapy Treatment Planning using Monte Carlo Simulation Aided by an Interface Software
Introduction: In brachytherapy, radioactive sources are placed close to the tumor, therefore, small changes in their positions can cause large changes in the dose distribution. This emphasizes the need for computerized treatment planning. The usual method for treatment planning of cervix brachytherapy uses conventional radiographs in the Manchester system. Nowadays, because of their advantages ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- IEEE transactions on medical imaging
دوره 28 12 شماره
صفحات -
تاریخ انتشار 2009