Comparison of the Multiple Reaction Monitoring and Enhanced Product Ion Scan Modes for Confirmation of Stilbenes in Bovine Urine Samples Using LC–MS/MS QTRAP® System
نویسندگان
چکیده
In accordance with Commission Decision 2002/657/EC, confirmatory methods for the detection of prohibited substances should comply with specific requirements, including the criteria for confirmation. Two strategies: multiple reaction monitoring (MRM) and enhanced product ion (EPI) scanning functions were compared for confirming the anabolic compounds from synthetic stilbenes group in bovine urine samples. In the research, twenty samples fortified at the Recommended Concentration (RC) of 1 µg L-1 with diethylstilbestrol, dienestrol and hexestrol were analyzed by liquid chromatography-tandem mass spectrometry on a QTRAP 5500 instrument. The analytical procedure, validated in accordance with the Commission Decision 2002/657/EC, used in the official control of hormones in Poland was applied. The validation parameters were in agreement with 2002/657/EC performance criteria. The effectiveness of MRM and EPI scanning modes for confirmation purposes was evaluated based on the percentage of the results confirmed. In all urine samples recorded in the MRM mode, the confirmation criteria (retention time, relative intensities between transitions) have been fulfilled. The presence of stilbenes in all urine samples using EPI scan mode was confirmed too as evidenced by a good matching of stilbenes spectra in the samples to the reference spectra with critical match factor above 0.7. The results of the research show that EPI scanning function provides the same effectiveness for confirmation of banned compounds as the mostly used MRM scan mode and can be an additional tool to confirm the doubtful case results in the analysis of hormones residues, even at such low concentration levels.
منابع مشابه
Analysis of Polycyclic Aromatic Hydrocarbons (PAH), Alkylated Derivatives, and Photo-degradation Products in Environmental and Food Samples using LC-FLD-MS/MS with Q TRAP Technology
A new liquid chromatography (LC) method was developed that separates 26 polycyclic aromatic hydrocarbons (PAH), 6 alkylated derivatives, and 11 photo-oxidation products in a single LC run followed by sensitive fluorescence detection (FLD) and tandem mass spectrometry (MS/MS). Hybrid triple quadrupole linear ion trap (4000 Q TRAP and QTRAP 5500 systems) were operated in highly selective Multiple...
متن کاملQuantification of Melittin in Iranian Honey Bee (Apis mellifera meda) Venom by Liquid Chromatography-electrospray Ionization-ion Trap Tandem Mass Spectrometry (LC-ESI-IT-MS/MS)
The current research aimed to quantify melittin (MEL) in Iranian honey bee (Apis mellifera meda) venom. To this end, a liquid chromatography-electrospray ionization-ion trap tandem mass spectrometry (LC-ESI-IT-MS/MS) approach was employed. Melittin is the main toxic peptide of honey bee venom with various biological and pharmacological activities. It was extracted with...
متن کاملSimultaneous determination of 10 nucleosides and nucleobases in Antrodia camphorata using QTRAP LC-MS/MS.
A liquid chromatography-triple-quadrupole linear ion trap mass spectrometry (LC-QTrap-MS) analysis has been developed for the identification and quantification of 10 nucleosides and nucleobases in extracts of Antrodia camphorata. The method was successfully used to qualitatively identify for six nucleosides namely, cytidine, uridine, inosine, guanosine, thymidine, adenosine and four nucleobases n...
متن کاملLibrary Search-based Drug Analysis in Forensic Toxicology by Liquid Chromatography–mass Spectrometry
Liquid chromatography–mass spectrometry (LC–MS) with electrospray (ES) ionization in the positive ion mode was applied to drug analysis in forensic toxicology. Several types of screening and confirmation strategies were developed, based essentially on searching of comprehensive MS libraries and databases that were created in-house for the purpose. Two spectral libraries, both containing spectra...
متن کاملDetermination of thiol metabolites in human urine by stable isotope labeling in combination with pseudo-targeted mass spectrometry analysis
Precursor ion scan and multiple reaction monitoring scan (MRM) are two typical scan modes in mass spectrometry analysis. Here, we developed a strategy by combining stable isotope labeling (IL) with liquid chromatography-mass spectrometry (LC-MS) under double precursor ion scan (DPI) and MRM for analysis of thiols in 5 types of human cancer urine. Firstly, the IL-LC-DPI-MS method was applied for...
متن کامل