A study on the fracture strength of collarless metal-ceramic fixed partial dentures

نویسندگان

  • Jong-Wook Yoon
  • Sung-Hun Kim
  • Jai-Bong Lee
  • Jung-Suk Han
  • Jae-Ho Yang
چکیده

PURPOSE The objective of this study was to evaluate fracture strength of collarless metal-ceramic FPDs according to their metal coping designs. MATERIALS AND METHODS Four different facial margin design groups were investigated. Group A was a coping with a thin facial metal collar, group B was a collarless coping with its facial metal to the shoulder, group C was a collarless coping with its facial metal 1 mm short of the shoulder, and group D was a collarless coping with its facial metal 2 mm short of the shoulder. Fifteen 3-unit collarless metal-ceramic FPDs were fabricated in each group. Finished FPDs were cemented to PBT (Polybutylene terephthalate) dies with resin cement. The fracture strength test was carried out using universal testing machine (Instron 4465, Instron Co., Norwood MA, USA) at a cross head speed of 0.5 mm/min. Aluminum foil folded to about 1 mm of thickness was inserted between the plunger tip and the incisal edge of the pontic. Vertical load was applied until catastrophic porcelain fracture occurred. RESULTS The greater the bulk of unsupported facial shoulder porcelain was, the lower the fracture strength became. However, there were no significant differences between experimental groups (P > .05). CONCLUSION All groups of collarless metal-ceramic FPDs had higher fracture strength than maximum incisive biting force. Modified collarless metal-ceramic FPD can be an alternative to all-ceramic FPDs in clinical situations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Collarless metal ceramic fixed partial denture: a clinical report.

A case of a collarless metal ceramic fixed partial denture with preparations made at a slightly supragingival level is reported. The absence of the metal collar in the buccal portion of the abutments provides an excellent esthetic appearance. The use of a collarless metal ceramic fixed partial denture is a viable approach for restoring dentition where the esthetic quality is the primary concern.

متن کامل

Marginal Strength of Collarless Metal Ceramic Crown

Metal ceramic restorations have been implicated for the discoloration in area of labiogingivalmargin. Attempts to rectify this, by altering the design of metal frameworkswill lead to decrease in fracture strength atmargin. This in vitro study compared the fracture strength at margins of metal ceramic crowns cemented to metal tooth analogs. Crowns evaluated with different marginal configurations...

متن کامل

Fracture Strength of Three-Unit Implant Supported Fixed Partial Dentures with Excessive Crown Height Fabricated from Different Materials

OBJECTIVES Fracture strength is an important factor influencing the clinical long-term success of implant-supported prostheses especially in high stress situations like excessive crown height space (CHS). The purpose of this study was to compare the fracture strength of implant-supported fixed partial dentures (FPDs) with excessive crown height, fabricated from three different materials. MATE...

متن کامل

Effect of Pontic Framework Design on the Fracture Resistance of Implant-supported All-ceramic Fixed Partial Dentures

OBJECTIVE The purpose of this study was to compare the fracture resistance of implant-supported all-ceramic fixed partial dentures, which have three different pontic designs. MATERIAL AND METHODS Two implants were placed in a metal model simulating mandibular left second premolar and mandibular left second molar. Thirty standardized 3-unit all-ceramic fixed partial dentures with biconvex, con...

متن کامل

Ceramic Restoration Repair: Report of Two Cases

The esthetic and functional rehabilitation of patients with multiple missing teeth can be performed with several techniques and materials. Ceramic restorations provide reliable masticatory function and good esthetics. However, fracture can occur in some cases due to their brittle behavior. In some cases, the replacement of an extensive prosthesis is a problem due to the high treatment cost. In ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2  شماره 

صفحات  -

تاریخ انتشار 2010