How safe and effective are existing treatments for wide-necked bifurcation aneurysms? Literature-based objective performance criteria for safety and effectiveness.

نویسندگان

  • David Fiorella
  • Adam S Arthur
  • Richard Chiacchierini
  • Evelyne Emery
  • Andy Molyneux
  • Laurent Pierot
چکیده

INTRODUCTION Wide-necked bifurcation aneurysms (WNBAs) present unique technical challenges for both endovascular and surgical treatments which aim to achieve complete occlusion of the aneurysm without compromising the patency of the incorporated regional parent vessels. We present a meta-analysis of traditional therapies for WNBAs to provide critical benchmarks for safety and effectiveness. METHODS Following a systematic search of the literature and the application of pre-specified appropriateness criteria, 43 (including 2794 aneurysms treated) and 65 (including 5366 patients treated) references with sufficient detail were identified to include in a meta-analysis of efficacy and safety, respectively. Effectiveness endpoints of both complete and adequate occlusion were assessed. A composite safety endpoint was based upon commonly applied metrics for major adverse events. Fleiss analyses were performed for both effectiveness and safety endpoints for the entire group, and then parsed separately by treatment modality (surgical clipping (SC) or endovascular therapy (EVT)) and location (anterior or posterior circulation). RESULTS Using the above methods, the core laboratory adjusted rate of complete occlusion was 46.3% (standard error 3.6%), 39.8% (3.7%), and 52.5% (9.6%) for all therapies, EVT, and SC, respectively. The rate of adequate occlusion was 59.4% (12.2%), 43.8% (5.3%), and 69.7% (14.3%) for all therapies, EVT, and SC, respectively. The rates of occurrence for pre-specified safety endpoints were 18.7% (2.9%), 21.1% (2.8%), and 24.3% (4.9%) for all therapies, EVT, and SC, respectively. CONCLUSIONS Conventional therapies for WNBAs are associated with relatively low rates of complete occlusion and peri-procedural complications are not uncommon. As new treatment technologies are investigated, it is important that the available data regarding predicate treatments is understood.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Misaligned pCONus Device: Case Report of a Unique Complication

pCONus is a stent-like endovascular device which aids in retention of coils within wide-necked bifurcation aneurysms. It is retrievable even after complete deployment and is detached electrolytically. The pCONus aided coiling of wide-necked bifurcation aneurysms has a high technical success rate and a good safety profile. Different complications have been described in literature with the usage ...

متن کامل

Identification and ranking of key indicators of health, safety, environment and energy education performance based on multi criteria decision making (MCDM)

Introduction: Health, safety, environment and energy management systems are one of the most popular models, and Implementing and deploying it will prevent waste of time and money. Execution, Continuity Optimal performance it requires effective training. The purpose of this study was to identify and rank important indicators for health, safety, environment and energy education. Methods: This re...

متن کامل

Safety, effectiveness and economic evaluation of intra-operative radiation therapy: a systematic review

  Background: Intra-operative radiation therapy (IORT) is the transfer of a single large radiation dose to the tumor bed during surgery with the final goal of improving regional tumor control. This study aimed to investigate the safety, effectiveness and economic evaluation of intra-operative radiation therapy.   Methods : The scientific literature was searched in the main biomedical databases ...

متن کامل

Y-configuration Stent-assisted Coil Embolization for Wide-necked Intracranial Bifurcation Aneurysms

OBJECTIVE The objective of this study was to determine the efficiency and safety of Y configuration stent-assisted coiling with double-closed stents for wide-necked intracranial aneurysms located at arterial bifurcations thorough analysis of a multicenter case series. MATERIALS AND METHODS A retrospective chart review was done on 10 patients who underwent endovascular treatment of wide-necked...

متن کامل

The Use of Solitaire AB Stents in Coil Embolization of Wide-Necked Cerebral Aneurysms

BACKGROUND The Solitaire AB stent is one of many assistant stents used for treating wide-necked cerebral aneurysm, and has been used since 2003. However, large sample studies on its safety and effectiveness are lacking. The objective of this study was to evaluate the effectiveness and safety of the Solitaire AB stent in the coil embolization of wide-necked cerebral aneurysms. METHODS Retrospe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of neurointerventional surgery

دوره 9 12  شماره 

صفحات  -

تاریخ انتشار 2017