A comparison of simultaneous measurements of systolic function in the baboon by electromagnetic flowmeter and high frame rate ECG-gated blood pool scintigraphy.
نویسندگان
چکیده
Left ventricular (LV) systolic timing and relative volume variations were simultaneously measured by electromagnetic flowmeter (EMF) and high frame rate ECG-gated blood pool scintigraphy in five baboons. No significant differences (p greater than 0.1, paired t test) were observed in the time (from R wave) to peak aortic flow (maximum LV ejection rate), time to cessation of aortic flow (end-systole) or in the duration of aortic flow (LV ejection time). A small (approximately 15 msec) but significant systematic difference (p less than 0.02) was noted in the time to onset of aortic flow. The shape of each scintigraphic time-activity curve during systole was compared to an equivalent curve synthesized from 10 EMF flow profiles obtained in the same baboon. Comparison of these paired curves over systolic ejection yielded an average correlation or r = 0.95 (range 0.90--0.99). The ratio of peak flow to stroke volume determined from these data did not differ significantly (p greater than 0.05). In the baboon, quantitative high temporal resolution ECG-gated scintigraphy appears to reflect closely the detailed timing and relative magnitude variation of LV volume during the entire period of systolic ejection. We conclude that the assumptions underlying the scintigraphic method are valid in the baboon during the ejection interval.
منابع مشابه
Diastolic left ventricular functional indices: Comparison between gated myocardial perfusion SPECT and echocardiography
Introduction: Many patients have only diastolic dysfunction without any abnormality in systolic function. We compared cardiac diastolic parameters obtained by gated myocardial perfusion SPECT (Gated SPECT) with those evaluated by echocardiography. Methods: Forty-nine patients (aged 37-85 years, 19 males and 30 women) underwent Gated SPECT and echocardiogr...
متن کاملLeft ventricular ejection and filling rate measurement based on the automatic edge detection method of ECG-gated blood pool single-photon emission tomography.
UNLABELLED The objective of the present investigation was to determine the feasibility of assessing left ventricular systolic ejection and diastolic filling via the automatic edge detection method employing ECG-gated blood pool single-photon emission tomography (SPET GBP) data. METHODS Thirty-five patients, who had undergone both SPET GBP and ECG-gated equilibrium blood pool scintigraphy by t...
متن کاملEvaluation of myocardial perfusion and function after kidney transplantation by Gated SPECT myocardial perfusion scintigraphy
Introduction: The aim of this study was to evaluate the effect of successful kidney transplantation (KT) on myocardial perfusion and left ventricular function by both qualitative (visual) interpretation and semiquantitative parameters, using myocardial perfusion scintigraphy with gated-single photon emission computed tomography (gated-SPECT) in patients suffering from end-stage renal disease. ...
متن کاملThe role of oral dipyridamole stress gated SPECT in assessing the response of the left ventricle to stress: Re-evaluation of an old method
Introduction: We aimed to assess whether the vasodilator effect of oral dipyridamole on the left ventricular systolic function in patients with suspected CAD is different from that of intravenous (IV) dipyridamole using Tc-99m MIBI myocardial perfusion gated SPECT. Methods: Eighty-nine patients (17 M / 72 W; 61 ± 10 years) were enrolled in this study. The patients underwent a dipyridamole stre...
متن کاملA new technique for assessing right ventricular ejection fraction using rapid multiple-gated equilibrium cardiac blood pool scintigraphy. Description, validation and findings in chronic coronary artery disease.
A reproducible, noninvasive technique for determining right ventricular ejection fraction (RVEF) was developed using multiple-gated equilibrium blood pool scintigraphy, which allows serial rapid measurements without reinjection of radioactivity. Studies were obtained using in vitro labeled technetium99m red blood cells, gamma camera and computer. In 20 patients, RVEF determined by multiple-gate...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation
دوره 60 2 شماره
صفحات -
تاریخ انتشار 1979