Harmonic Motion Imaging – Applications in the Detection of Stiffer Masses
نویسندگان
چکیده
The technique of Harmonic Motion Imaging (HMI) utilizes the localized stimulus of the oscillatory ultrasonic radiation force as produced by two overlapping beams of distinct frequencies, and estimates the resulting harmonic displacement in the tissue in order to assess its underlying mechanical properties. In this paper, we studied the relationship between the measured displacement and the gel/tissue stiffness. Two focused transducers with a 100 mm focus were used at the frequencies of 3.7500 MHz and 3.7502 MHz (or, 3.7508 MHz depending on the case), respectively, in order to produce an oscillatory motion at 200 Hz in the gel (or, 800 Hz in the tissue). A 1.1 MHz diagnostic transducer (Imasonics, Inc.) was also focused at 100 mm and acquired RF signals of 5 ms in total duration (PRF =3.5 kHz) at 100 MHz sampling frequency during radiation force application. First, three acrylamide gels of 50 x 50 mm were prepared at concentrations of 4%, 8% and 16%. The resulting displacement was estimated using crosscorrelation techniques between successively acquired RF signals with a 2 mm window and 80% window overlap at 1260 W/cm. A 1-D normal indentation instrument (TeMPeST) applied oscillatory loads at 0.5-200 Hz with a 5 mm-diameter flat indenter. Then, 12 displacement measurements in six ex vivo porcine muscle specimens (2 measurements/case) were made using 1260 W/cm, before and after ablation for 10s at 1260 W/cm. In all gel cases, the harmonic displacement was found to steadily decrease with gel concentration. The TeMPeST measurements showed that the elastic moduli for the 4%, 8% and 16% gels equaled 3.93+/-0.06kPa, 17.1+/-0.2kPa and 75+/-2kPa, respectively; demonstrating, thus, that the HMI displacement estimate depends directly on the gel stiffness. Finally, in the ex vivo tissues, the mean displacement amplitude showed a two-fold decrease between non-ablated and ablated tissue; depicting thus the stiffness dependence of the HMI response in tissues.
منابع مشابه
Dynamic Stability Analysis of a Beam Excited by a Sequence of Moving Mass Particles
In this paper, the dynamic stability analysis of a simply supported beam carrying a sequence of moving masses is investigated. Many applications such as motion of vehicles or trains on bridges, cranes transporting loads along their span, fluid transfer pipe systems and the barrel of different weapons can be represented as a flexible beam carrying moving masses. The periodical traverse of masses...
متن کاملUse of imaging techniques in detection of parotid masses Location compared to surgery
Objective: The purpose of this study was to compare the use of cross-sectional imaging techniques verses surgery in locating parotid masses. Material and Methods: Our study was performed on patients assumed to have parotid masses from Dec 2010 to Dec 2011. Before surgery, imaging studies (Computed Tomography and Magnetic Resonance Imaging) of parotid were done. After surgery, we compared the s...
متن کاملMotion detection by a moving observer using Kalman filter and neural network in soccer robot
In many autonomous mobile applications, robots must be capable of analyzing motion of moving objects in their environment. Duringmovement of robot the quality of images is affected by quakes of camera which cause high errors in image processing outputs. In thispaper, we propose a novel method to effectively overcome this problem using Neural Networks and Kalman Filtering theory. Thistechnique u...
متن کاملAdvanced Motion Correction Methods in PET
With the arrival of increasingly higher resolution PET systems, small amounts of motion can cause significant blurring in the images, compared to the intrinsic resolutions of the scanners. In this work, we have reviewed advanced correction methods for the three cases of (i) unwanted patient motion, as well as motions due to (ii) cardiac and (iii) respiratory cycles. For the first type of ...
متن کاملاصلاح حرکت در تصویربرداری اسپکت میوکارد با استفاده از مدلسازی منحنی چند جمله ای
Background and purpose: Patient motion during myocardial perfusion SPECT can produce artifacts in reconstructed images which might affect clinical diagnosis. This paper attempts to present a new approach for the detection and correction of cardiac motion utilizing the data obtained during the imaging process. Materials and methods: Our method quantifies motion through polynomial curves modelin...
متن کامل