The Effect of Treatment Position on Rectal and Bladder Dose-Volume Histograms for Prostate Radiotherapy Planned with 3-Dimensional Conformal Radiotherapy, Intensity-Modulated Radiotherapy and Volumetric Modulated Arc Therapy
نویسندگان
چکیده
Purpose: To compare target coverage and organ at risk (OAR) sparing in the supine and prone positions with 3-dimensional conformal radiotherapy (3DCRT), intensity-modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT) in lowand high-risk prostate radiotherapy cases. Materials and Methods: Using magnetic resonance images of five healthy volunteers, six treatment plans (supine 3DCRT, prone 3DCRT, supine IMRT, prone IMRT, supine VMAT and prone VMAT) were generated. Planning target volume 1 (PTV1) was defined as the prostate gland plus the seminal vesicles with adequate margins in a high-risk setting, while PTV2 was defined as prostate only with margins in a low-risk setting. The mean dose for both PTV1 and PTV2 was set at 78 Gy. Plans generated by each of the 3 techniques were compared between the supine and prone positions using dose-volume histograms (DVHs). Results: For PTV1, prone 3DCRT provided a significantly higher D98% than did supine 3DCRT, and its homogeneity index (HI) was significantly better. IMRT and VMAT values did not differ significantly between the prone and supine positions. For PTV2, no values differed significantly between the supine and prone positions under any treatment plan. With respect to OAR, the rectal Dmean, D2%, V50, and V60 values of PTV1 were
منابع مشابه
3-Dimensional conformal radiotherapy versus intensity modulated radiotherapy for localized prostate cancer: Dosimetric and radiobiologic analysis
Background: To analyze the dosimetric and radio biologic advantages between intensity modulated radiotherapy (IMRT) and 3 dimensional conformal radiotherapy (3DCRT) and selection of optimal photon energy for IMRT treatments. Material and methods: 24 patients with localized prostate carcinoma were planned for 3DCRT and IMRT techniques. Radiation dose of 54 Gy with 2 Gy/fraction, was planned to ...
متن کاملEarly toxicity of moderate hypofractionated volumetric modulated Arc radiotherapy for localized prostate cancer
Background: Based on the radiation biology model of prostate cancer, hypofractionated radiotherapy can improve the treatment outcomes without increasing toxicity. Although hypofractionated radiotherapy is implemented over a short period of time, it is more convenient and cheaper compared with conventional fractionated treatment. The aim of this study was to investigate the early toxicity of mod...
متن کاملDosimetric comparison of 3-dimensional conformal and intensity-modulated radiotherapy techniques for whole breast irradiation in the prone and supine positions
Background: The aim of this study was to compare the differences of the dosimetric parameters between three-dimensional conformal radiotherapy (3D-CRT) and simultaneous-integrated boost intensity-modulated radiotherapy (SIB-IMRT) techniques in the prone and supine positions for breast irradiation. Materials and Methods: Ten patients underwent a computed tomography simulation in both the prone a...
متن کاملAssessment and Comparison of Homogeneity and Conformity Indexes in Step-and-Shoot, Compensator-Based Intensity Modulated Radiation Therapy (IMRT) and Three-Dimensional Conformal Radiation Therapy (3D CRT) in Prostate Cancer
Introduction: Intensity modulated radiation therapy (IMRT) and three-dimensional conformal radiation therapy (3D CRT) are two treatment modalities in prostate cancer, which provide acceptable dose distribution in tumor region with sparing the surrounding normal tissues. IMRT is based on inverse planning optimization; in which, intensity of beams is modified by using multileaf c...
متن کاملDosimetric Evaluation of Volumetric Modulated Arc Therapy (VMAT) and Intensity Modulated Radiotherapy (IMRT) Using AAPM TG 119 Protocol
Background: The commissioning accuracy of Volumetric Modulated Arc Therapy (VMAT) need to be evaluated.Objective: To test and evaluate commissioning accuracy of VMAT based on the TG 119 protocols at local institution. Material and Methods: The phantom, structure sets, VMAT and IMRT beam parameter setup, dose prescriptions and planning objectives were following TG 119 guidelines to c...
متن کامل