Structured CsI(Tl) Scintillators for X-ray Imaging Applications

نویسندگان

  • V. V. Nagarkar
  • T. K. Gupta
  • G. Entine
چکیده

We are developing large-area, thick, structured CsI(Tl) imaging sensors for a wide variety of X-ray imaging applications. Recently we have fabricated structured CsI(Tl) scintillators ranging from 30 μm (16 mg/cm) to 2000 μm (900 mg/cm) in thickness and up to 15 x 15 cm in area. Even 2000-μm-thick film showed well-controlled columnar growth throughout the film. Material characterization confirmed that the film is crystalline in nature and that the stoichiometry is preserved. To improve the spatial resolution of thick films, post-deposition treatments were performed. The effect of these treatments on film characteristics was quantitatively evaluated by measuring signal output, modulation transfer function [MTF(f)], noise power spectrum [NPS(f)], and detective quantum efficiency [DQE(f)]. The data show that by proper film treatments, the film DQE(f) can be improved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Characterization of scintillator-based detectors for few-ten-keV high-spatial-resolution x-ray imaging.

PURPOSE High-spatial-resolution x-ray imaging in the few-ten-keV range is becoming increasingly important in several applications, such as small-animal imaging and phase-contrast imaging. The detector properties critically influence the quality of such imaging. Here the authors present a quantitative comparison of scintillator-based detectors for this energy range and at high spatial frequencie...

متن کامل

X-ray imaging performance of structured cesium iodide scintillators.

Columnar structured cesium iodide (CsI) scintillators doped with Thallium (Tl) have been used extensively for indirect x-ray imaging detectors. The purpose of this paper is to develop a methodology for systematic investigation of the inherent imaging performance of CsI as a function of thickness and design type. The results will facilitate the optimization of CsI layer design for different x-ra...

متن کامل

Growth of CsI(Tl) crystals doped with Ca and Tm and investigation of its scintillation characteristics

In this work, the growth of CsI(Tl) crystals as gamma detector was performed using vertical Bridgman method with Ca and Tm co-dopants. For evaluation of the growth crystals, X-Ray Diffraction (XRD), photoluminescence and thermoluminescence spectra as well as recorded gamma spectra were employed. In addition, the scintillation properties including energy resolution, scintillation decay time, abs...

متن کامل

Studies of Prototype CsI(Tl) Crystal Scintillators for Low-Energy Neutrino Experiments

Crystal scintillators provide potential merits for the pursuit of low-energy low-background experiments. A CsI(Tl) scintillating crystal detector is being constructed to study lowenergy neutrino physics at a nuclear reactor, while projects are underway to adopt this technique for dark matter searches. The choice of the geometrical parameters of the crystal modules, as well as the optimization o...

متن کامل

Recent progress of avalanche photodiodes in high-resolution X-rays and γ-rays detection

We have studied the performance of large area avalanche photodiodes (APDs) recently developed by Hamamatsu Photonics K.K, in high-resolution X-rays and γrays detections. We show that reach-through APD can be an excellent soft X-ray detector operating at room temperature or moderately cooled environment. We obtain the best energy resolution ever achieved with APDs, 6.4 % for 5.9 keV X-rays, and ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1998