A biomechanical comparison of two patterns of screw insertion.
نویسندگان
چکیده
Inserting a screw into a long bone introduces a stress riser that can predispose the bone to fracture. Where multiple screws are inserted this vulnerability may be increased. It is thought that the pattern of screw insertion plays an important part in determining the susceptibility of the bone to stress fracture. In order to study the importance of pattern of screw insertion, third generation composite femora with cannulated screws inserted in two different patterns were tested to failure by a servohydraulic materials test system. The vertical pattern of screw insertion is less apt to predispose a long bone to subsequent fracture than a horizontal pattern.
منابع مشابه
Biomechanical Comparison Between Bashti Bone Plug Technique and Biodegradable Screw for Fixation of Grafts in Ligament surgery
Background: Ligament reconstruction is a common procedure in orthopedic surgery. Although several popular techniques are currently in use, new methods are proposed for secure fixation of the tendon graft into the bone tunnel. Purposes: We sought to introduce our new technique of Bashti bone plug for fixation of soft tissue graft in anterior cruciate ligament (ACL) reconstruction and to compar...
متن کاملComparison of Expansive Pedicle Screw and Polymethylmethacrylate-Augmented Pedicle Screw in Osteoporotic Sheep Lumbar Vertebrae: Biomechanical and Interfacial Evaluations
BACKGROUND It was reported that expansive pedicle screw (EPS) and polymethylmethacrylate-augmented pedicle screw (PMMA-PS) could be used to increase screw stability in osteoporosis. However, there are no studies comparing the two kinds of screws in vivo. Thus, we aimed to compare biomechanical and interfacial performances of EPS and PMMA-PS in osteoporotic sheep spine. METHODOLOGY/PRINCIPAL F...
متن کاملThe effect of screw angulation and insertion torque on the push-out strength of polyaxial locking screws and the single cycle to failure in bending of polyaxial locking plates.
OBJECTIVE To evaluate the mechanical properties of the Polyaxial Advanced Locking System (PAX) in screw push-out and four-point bending. MATERIALS AND METHODS Screw push-out: PAX locking screws were applied to first generation PAX plates at three different insertion angles with two different insertion torques. A load was applied parallel to the screw axis, and screw push-out force was measure...
متن کاملBiomechanical study of the funnel technique applied in thoracic pedicle screw replacement.
BACKGROUND Funnel technique is a method used for the insertion of screw into thoracic pedicle. AIM To evaluate the biomechanical characteristics of thoracic pedicle screw placement using the Funnel technique, trying to provide biomechanical basis for clinical application of this technology. METHODS 14 functional spinal units (T6 to T10) were selected from thoracic spine specimens of 14 fres...
متن کاملBiomechanical comparison of pullout strengths of five cortical screw types: An innovative measurement method.
OBJECTIVES This study aims to assess five different cortical screw types using artificial femurs, under equated testing conditions. MATERIALS AND METHODS We investigated the maximum force needed to cause deformation at screw-bone interface using fourth generation composite femurs by conducting separate pullout tests for each screw type. We normalized obtained results with traditional methods ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Bulletin of the NYU hospital for joint diseases
دوره 66 4 شماره
صفحات -
تاریخ انتشار 2008