Methods to estimate aspects of physical activity and sedentary behavior from high-frequency wrist accelerometer measurements.

نویسندگان

  • John Staudenmayer
  • Shai He
  • Amanda Hickey
  • Jeffer Sasaki
  • Patty Freedson
چکیده

This investigation developed models to estimate aspects of physical activity and sedentary behavior from three-axis high-frequency wrist-worn accelerometer data. The models were developed and tested on 20 participants (n = 10 males, n = 10 females, mean age = 24.1, mean body mass index = 23.9), who wore an ActiGraph GT3X+ accelerometer on their dominant wrist and an ActiGraph GT3X on the hip while performing a variety of scripted activities. Energy expenditure was concurrently measured by a portable indirect calorimetry system. Those calibration data were then used to develop and assess both machine-learning and simpler models with fewer unknown parameters (linear regression and decision trees) to estimate metabolic equivalent scores (METs) and to classify activity intensity, sedentary time, and locomotion time. The wrist models, applied to 15-s windows, estimated METs [random forest: root mean squared error (rSME) = 1.21 METs, hip: rMSE = 1.67 METs] and activity intensity (random forest: 75% correct, hip: 60% correct) better than a previously developed model that used counts per minute measured at the hip. In a separate set of comparisons, the simpler decision trees classified activity intensity (random forest: 75% correct, tree: 74% correct), sedentary time (random forest: 96% correct, decision tree: 97% correct), and locomotion time (random forest: 99% correct, decision tree: 96% correct) nearly as well or better than the machine-learning approaches. Preliminary investigation of the models' performance on two free-living people suggests that they may work well outside of controlled conditions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Standing Handball Throwing Velocity Estimation with a Single Wrist-Mounted Inertial Sensor

Background. It is well known that overarm throwing is one of the most performed activities in the handball. Shoulder and glenohumeral injuries incidence are high in handball because of both pass, and shooting activity was executed repeatedly in high angular speed. Objectives. This study set out to investigate the usefulness of inexpensive commercial inertial movement sensors for prediction of ...

متن کامل

Validation and Comparison of Accelerometers Worn on the Hip, Thigh, and Wrists for Measuring Physical Activity and Sedentary Behavior

Background Recent evidence suggests that physical activity (PA) and sedentary behavior (SB) exert independent effects on health. Therefore, measurement methods that can accurately assess both constructs are needed. Objective To compare the accuracy of accelerometers placed on the hip, thigh, and wrists, coupled with machine learning models, for measurement of PA intensity category (SB, light-...

متن کامل

Number of Days Required to Estimate Habitual Activity Using Wrist-Worn GENEActiv Accelerometer: A Cross-Sectional Study

INTRODUCTION Objective methods like accelerometers are feasible for large studies and may quantify variability in day-to-day physical activity better than self-report. The variability between days suggests that day of the week cannot be ignored in the design and analysis of physical activity studies. The purpose of this paper is to investigate the optimal number of days needed to obtain reliabl...

متن کامل

Calibration of the global physical activity questionnaire to Accelerometry measured physical activity and sedentary behavior

BACKGROUND Self-report questionnaires are a valuable method of physical activity measurement in public health research; however, accuracy is often lacking. The purpose of this study is to improve the validity of the Global Physical Activity Questionnaire by calibrating it to 7 days of accelerometer measured physical activity and sedentary behavior. METHODS Participants (n = 108) wore an ActiG...

متن کامل

Calibration and Validation of a Wrist- and Hip-Worn Actigraph Accelerometer in 4-Year-Old Children

INTRODUCTION To determine time spent at different physical activity intensities, accelerometers need calibration. The aim of this study was to develop and cross-validate intensity thresholds for the Actigraph GT3X+ accelerometer for wrist and hip placement in four-year-old children. METHODS In total 30 children (49 months, SD 3.7) were recruited from five preschools in Stockholm. Equipped wit...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of applied physiology

دوره 119 4  شماره 

صفحات  -

تاریخ انتشار 2015