A flow-cytometric method for continuous measurement of intracellular Ca(2+) concentration.
نویسندگان
چکیده
Alterations in intracellular Ca(2+) concentration are amongst the most rapid responses to a variety of stimuli in mammalian cells. In the nervous system in particular, responses occur within nanoseconds. A major challenge in intracellular Ca(2+) analysis is to achieve measurements within this very fast time frame. To date, the dynamic intracellular Ca(2+) concentration has been monitored by confocal microscopy, plate-based assays, spectrofluorometry, and flow cytometry, although there are issues with the number of cells analyzed or gaps in recording due to the addition of compounds, with significant loss of detail of a rapid Ca(2+) response. The new generation of flow cytometers (such as Accuri C6) resolves this problem by allowing the addition of test compounds with continuous monitoring of thousands of cells, providing a method for dynamic Ca(2+) measurements. This system was tested with commonly used Ca(2+) modulating agents in C6 glioma cells. Thapsigargin (TG), a blocker of Ca(2+) uptake into the endoplasmic reticulum (ER), causes a significant increase in the intracellular calcium concentration via ER emptying followed by Ca(2+) entry via store-operated Ca(2+) channels (SOCC). This well-established pathway can be partially inhibited by 2-aminoethoxydiphenyl borate (2-APB), a blocker of SOCC. Both the increase with TG alone and the partial increase when coincubated with 2-APB were observed with continuous recording along with calibration curves using an Accuri C6 flow cytometer. With these new cytometers, dynamic Ca(2+) concentration measurement becomes extremely accessible and accurate, while also providing extensive and valuable data regarding population health and responsiveness.
منابع مشابه
Flow Cytometric Measurement of CD41/CD61 and CD42b Platelet Receptors and Clotting Assay of Platelet Factor 3 During Long Term-Storage of Platelet Concentrates
Background: The purpose of the present in vitro study was to evaluate the effect of long term storage of conventional platelet concentrates (PCs) on major platelet receptors CD42b and CD41/CD61 by flow cytometry method and also measuring the overall platelet procoagulant activity status using platelet factor 3 (PF3) assay. Materials and Methods: Six random units of conventional platelet conce...
متن کاملFlow cytometric analysis of herpes simplex virus type 1 susceptibility to acyclovir, ganciclovir, and foscarnet.
We established a quantitative flow cytometric method for determination of herpes simplex virus type 1 (HSV-1) susceptibility to acyclovir (ACV), ganciclovir, and foscarnet in vitro. Susceptibility was defined in terms of the drug concentration which reduced the number of cells expressing HSV-1 glycoprotein C (gpC) with a fluorescence intensity of > or =10(2) by 50% (IC50). Flow cytometry allowe...
متن کاملInhibition of CatSper and Hv1 Channels and NOX5 Enzyme Affect Progesterone-Induced Increase of Intracellular Calcium Concentration and ROS Generation in Human Sperm
Background: Normal sperm function depends on appropriate intracellular calcium (Cai2+) and reactive oxygen species (ROS) levels. Calcium activates NADPH oxidase-5 (NOX5) that leads to ROS generation. The calcium channel of sperm (CatSper) is activated by progesterone and intracellular alkalization. Herein, the interactive role of CatSper, Hv1 channels, and NOX5 enzyme on Cai2+ and ROS generatio...
متن کاملFlow Cytometric Measurement of CD41/CD61, CD42b Platelet Receptors and Platelet Factor 3 Activity in Lyophilized Infusible Platelet Membrane Preparation
Background: The short life time of human platelet units has led to a chronic shortage of fresh platelets in blood transfusion centers. Many approaches have been investigated experimentally to produce new hemostatically active platelet products that are capable of long term storage. Infusible platelet membrane (IPM) prepared from fresh or outdated human platelets have been developed as an altern...
متن کاملDirect nitric oxide measurement in human spermatozoa: flow cytometric analysis using the fluorescent probe, diaminofluorescein.
We have demonstrated that intracellular nitric oxide (NO) can be detected and measured directly in human spermatozoa by flow cytometry using the fluorescent probe 4,5-diaminofluorescein-2/diacetate (10 microM). This method can measure both exogenously added as well as endogenously generated intracellular NO.
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Cytometry. Part A : the journal of the International Society for Analytical Cytology
دوره 77 11 شماره
صفحات -
تاریخ انتشار 2010