Assessment of Body Doses from Photon Exposures Using Human Voxel Models
نویسنده
چکیده
For the scope of risk assessment in protection against ionising radiation (occupational, environmental and medical) it is necessary to determine the radiation dose to specific body organs and tissues. For this purpose, a series of models of the human body were designed in the past, together with computer codes simulating the radiation transport and energy deposition in the body. Most of the computational body models in use are so-called mathematical models; the most famous is the MIRD-5 phantom developed at Oak Ridge National Laboratory. In the 1980s, a new generation of human body models was introduced at GSF, constructed from whole body CT data. Due to being constructed from image data of real persons, these "voxel models" offer an improved realism of external and internal shape of the body and its organs, compared to MIRD-type models. Comparison of dose calculations involving voxel models with respective dose calculations for MIRD-type models revealed that the deviation of the individual anatomy from that described in the MIRD-type models indeed introduces significant deviations of the calculated organ doses. Specific absorbed fractions of energy released in a source organ due to incorporated activity which are absorbed in target organs may differ by more than an order of magnitude between different body models; for external photon irradiation, the discrepancies are more moderate.
منابع مشابه
Organ doses from environmental exposures calculated using the ICRP Reference Male and Reference Female voxel phantoms
In its recent recommendations the ICRP adopted two voxel models of an adult male and an adult female to be used for the forthcoming update of organ dose conversion coefficients. These voxel models are representative of an average population, i.e. they resemble the ICRP reference anatomical data with respect to their external dimensions and their organ masses and were constructed for this purpos...
متن کاملThe Monte Carlo Assessment of Photon Organ Doses from 222Rn Progeny in Adult ORNL Phantom
Introduction The potential hazards posed by exposure to radiation from radon have been of great concern worldwide, since it is especially associated with increased risk of lung cancer. Some radioisotopes of radon progeny deposited in the human lungs emit β particles followed by the γ rays. While γ rays are comparatively less damaging to the respiratory system than α and β particles, it is the p...
متن کاملEstimation of Photon Specific Absorbed Fractions in Digimouse Voxel Phantom using Monte Carlo Simulation Code FLUKA
Background: Most preclinical studies are carried out on mice. For internal dose assessment of a mouse, specific absorbed fraction (SAF) values play an important role. In most studies, SAF values are estimated using older standard human organ compositions and values for limited source target pairs.Objective: SAF values for monoenergetic photons of energies 15, 50, 100, 500, 1000 and 4000 keV...
متن کاملHybrid Phantom Applications to Nuclear Medicine
Annually, many people are irradiated for diagnostic and therapeutic purposes. Assessment of radiation dose and its related risks to patients are important issues in radiation protection dosimetry. The complex mathematical calculations of the absorbed and effective doses are now done with computers. The calculations are performed with the help of anthropomorphic computational models of human bod...
متن کاملAssessment of whole-body occupational radiation exposures in nuclear medicine practices of Bangladesh during 2010-2014
Introduction: Occupational exposure to ionizing radiation due to medical activities (both diagnostic and therapeutic procedures) has increased sharply in recent years. Among the occupationally exposed workers in these fields, those most affected by this increased exposure to ionizing radiation are nuclear medicine workers. In this study, annual average effective dose, annual collective effectiv...
متن کامل