Measurement of Eardrum Acoustic Impedance
نویسنده
چکیده
In this paper we describe a system which we have developed to measure cat ear canal specific acoustic impedance Zsp, magnitude and phase, as a function of frequency, for frequencies between 200 Hz and 33 kHz, and impedance magnitude between 4.0 to 4.0×105 [Rayles] (MKS). The object to be measured is placed at the end of a 3.5 mm diameter sound delivery tube. After a simple calibration procedure, which determines the Thevenin parameters for the acoustic source transducer, the impedance may be calculated from the pressure measured at the orifice of the delivery tube with the unknown load in place. This procedure allows for a fast but accurate measure of a specific acoustic impedance. The system has been tested by measuring the impedance of a long cavity and comparing this response to the exact solution of the linearized Navier Stokes equations (acoustic equations including viscosity and thermal conduction). We have used this system to measure the impedance of the normal cat tympanic membrane in more than 30 cats. Healthy animals were found to have a real input impedance of ρc between 0.3 to 20.0 kHz. When the scala vestibuli was drained, the real part of the impedance dropped to less than ρc/10 for frequencies less than 3.0 kHz. Above 3 kHz, the impedance for the drained cochlea is best described by an open circuited transmission line.
منابع مشابه
Analysis of the Middle-Ear Function. Part I: Input Impedance
A quantitative theory of the middle-ear acoustics i developed and expressed interms of an electric analog. The analog network is based on the functional anatomy of the middle ear. The numerical values of its elements are derived from impedance measurements on normal and pathological ears and from anatomical data. It is shown that the input impedance of the analog agrees within the experimental ...
متن کاملEARDRUM DISPLACEMENT FOLLOWING STAPEDIUS MUSCLE CONTRACTION by
Simultaneous monitoring in human subjects on the same ear of eardrum displacement by tympanomanometry, and acoustical impedance by the Madsen bridge, provided information concerning contraction of the stapedius muscle and its effect on eardrum displacement. Extensive control procedures were employed to elicit only the stapedius reflex: lower intensity auditory stimulation, electrocutaneous stim...
متن کاملEvaluation of human middle ear function via an acoustic power assessment.
Measurements of middle ear (ME) acoustic power flow (power reflectance, power absorption, and transmittance) and normalized impedance (acoustic resistance, acoustic reactance, and impedance magnitude) were compared for their utility in clinical applications. Transmittance, a measure of the acoustic power absorbed by the ME, was found to have several important advantages over other measures of a...
متن کاملMeasurement of acoustic impedance and reflectance in the human ear canal.
The pressure reflectance R (omega) is the transfer function which may be defined for a linear one-port network by the ratio of the reflected complex pressure divided by the incident complex pressure. The reflectance is a function that is closely related to the impedance of the 1-port. The energy reflectance R (omega) is defined as magnitude of [R]2. It represents the ratio of reflected to incid...
متن کاملNon-invasive estimation of middle-ear input impedance and efficiency.
A method to transform the impedance measured in the ear canal, ZEC, to the plane of the eardrum, ZED, is described. The portion of the canal between the probe and eardrum was modeled as a concatenated series of conical segments, allowing for spatial variations in its cross-sectional area. A model of the middle ear (ME) and cochlea terminated the ear-canal model, which permitted estimation of ME...