Variables predictive of voiding disfunction following aponeurotic sling surgery: multivariate analysis.
نویسندگان
چکیده
INTRODUCTION Aponeurotic sling surgeries can evolve with obstruction or voiding dysfunction in 5 to 20% of patients. There are few studies on factors that could possibly predispose to voiding difficulties or urinary retention. The objective of this work is to identify these potential clinical or urodynamic factors. MATERIALS AND METHODS Records from 130 patients who underwent aponeurotic sling surgeries were reviewed. All patients underwent a throughout urodynamic study during pre-operative investigation. The variables studied were age above 65 years, previous pelvic surgeries, concomitant surgeries, post-voiding residue higher than 100 mL, vesical obstruction (according to Blaivas-Groutz nomogram) and urinary flow under 12 mL/s. Post-voiding residue was assessed on the seventh post-operative day through vesical catheterization. Recovering of spontaneous voiding after 7 post-operative days or with a residue higher than 100 mL, was regarded as voiding dysfunction. Univariate analysis was performed with qui-square test and Fisher's exact test, and multivariate analysis was performed by logistic regression with alpha = 5%. RESULTS Age in the studied group ranged from 41 to 83 years (mean 56.7 years), with 69 (53%) patients having urethral hypermobility and 61 (47%) having intrinsic urethral lesion. Normal voiding occurred in 97 (75.6%) women with 7 post-operative days. The only significant variable in the univariate (p = 0.014) and multivariate (p = 0.017) analysis was post-voiding residue higher than 100 mL. CONCLUSION Pre-operative presence of a post-voiding residual urine higher than 100 mL was the only variable predictive of voiding dysfunction.
منابع مشابه
Predictive factors for voiding dysfunction after transobturator slings.
PURPOSE To identify the predictive factors for voiding dysfunction after transobturator slings. METHODS We retrospectively reviewed the records of all patients who underwent a transobturator sling between March 2003 and December 2008. A total of 514 women had available data with at least a six-week follow-up. Patients' demographics, preoperative symptoms, urodynamic testing including multicha...
متن کاملPredictors of Voiding Dysfunction after Mid-urethral Sling Surgery for Stress Urinary Incontinence
PURPOSE Postoperative voiding dysfunction is a bothersome complication after mid-urethral sling surgery. The current study presents multiple repeated postoperative voiding trials against a urine load of preoperative functional bladder capacity, as estimated by a preoperative frequency volume chart, to identify the relevance of preoperative and immediate factors to the outcome. METHODS A total...
متن کاملPredictors of early postoperative voiding dysfunction and other complications following a midurethral sling.
BACKGROUND The rates reported for postoperative urinary retention following midurethral sling procedures are highly variable. Determining which patients have a higher likelihood of failing a voiding trial will help with preoperative counseling prior to a midurethral sling. OBJECTIVE The objective of the study was to identify preoperative predictors for failed voiding trial following an isolat...
متن کاملFunctional outcomes for surgical revision of synthetic slings performed for voiding dysfunction: a retrospective study.
OBJECTIVE To determine the functional outcomes after synthetic sling revision surgery performed for voiding dysfunction. STUDY DESIGN A retrospective review of 63 women who underwent surgical revision of a synthetic sling (SS) over an 11 year period between 2000 and 2010 inclusive, for the treatment of voiding dysfunction. Voiding dysfunction was defined as a persistently raised post-void res...
متن کاملVoiding dysfunction following removal of eroded synthetic mid urethral slings.
PURPOSE Voiding dysfunction following genitourinary erosion of synthetic mid urethral slings is not clearly reported. We investigated the incidence of voiding dysfunction in patients following sling excision due to vaginal, urethral or intravesical mesh erosion. MATERIALS AND METHODS Retrospective review identified 19 patients with genitourinary erosion of polypropylene mesh slings. Comprehen...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- International braz j urol : official journal of the Brazilian Society of Urology
دوره 30 4 شماره
صفحات -
تاریخ انتشار 2004