SA2RAGE: a new sequence for fast B1+ -mapping.
نویسندگان
چکیده
At high magnetic field strengths (≥ 3T), the radiofrequency wavelength used in MRI is of the same order of magnitude of (or smaller than) the typical sample size, making transmit magnetic field (B1+) inhomogeneities more prominent. Methods such as radiofrequency-shimming and transmit SENSE have been proposed to mitigate these undesirable effects. A prerequisite for such approaches is an accurate and rapid characterization of the B1+ field in the organ of interest. In this work, a new phase-sensitive three-dimensional B1+-mapping technique is introduced that allows the acquisition of a 64 × 64 × 8 B1+-map in ≈ 20 s, yielding an accurate mapping of the relative B1+ with a 10-fold dynamic range (0.2-2 times the nominal B1+). Moreover, the predominant use of low flip angle excitations in the presented sequence minimizes specific absorption rate, which is an important asset for in vivo B1+-shimming procedures at high magnetic fields. The proposed methodology was validated in phantom experiments and demonstrated good results in phantom and human B1+-shimming using an 8-channel transmit-receive array.
منابع مشابه
Sa2RAGE - A new sequence for rapid 3D B1-mapping with a wide sensitivity range
Introduction: At high magnetic field strengths (≥3T) the RF wavelength becomes smaller than the sample size, making transmit magnetic field (B1) inhomogeneity more prominent. RF-shimming [1] and Transmit SENSE [2] have been proposed as methods to minimize this inhomogeneity. To take advantage of these methods it is important to accurately map the B1 field. Saturation prepared with 2 RApid Gradi...
متن کاملRegularized Estimation of Magnitude and Phase of Multi-Coil $B_1$ Field Via Bloch-Siegert $B_1$ Mapping and Coil Combination Optimizations
Parallel excitation requires fast and accurate B1 map estimation. Bloch-Siegert (BS) B1 mapping is very fast and accurate over a large dynamic range. When applied to multi-coil systems, however, this phase-based method may produce low signal-to-noise ratio estimates in low magnitude regions due to localized excitation patterns of parallel excitation systems. Also, the imaging time increases wit...
متن کاملFast T1/B1 Mapping using multiple dual TR RF-spoiled Steady-State Gradient-Echo Sequences
Introduction: Dynamic Contrast-Enhanced MRI (DCE-MRI) is widely applied to assess tissue perfusion and vascular permeability [1]. In most of these applications, a T1 map, obtained prior to contrast agent (CA) administration, is used to convert the signal intensity from a series of T1-weighted spoiled gradient-echo images into CA concentration. The accuracy of the approach is mainly affected by ...
متن کاملSignal to Noise Ratio Analysis of Bloch-Siegert B1 Mapping
Introduction: B1 mapping is important in a variety of new MR applications, including the design of RF pulses in parallel transmit systems and flip angle calibration for T1 mapping. The Bloch-Siegert (BS) B1 mapping method has been recently introduced as a fast, accurate and robust technique for B1 mapping [1]. In order to compare the quality of B1 maps acquired with the BS method to other metho...
متن کاملTurbo Spin Echo Bloch Siegert Shift B1 Mapping
An interesting method for B1 mapping based on the Bloch-Siegert (BLS) shift was recently presented (1,2) for gradient echo (FLASH) and Spin Echo (SE) sequences. This method uses off-resonant pulses before signal acquisition to encode the B1 information into the signal phase. Fast B1 mapping is possible since the repetition time has only minor influence on the quality of the phase information. I...