A novel use of the Reciproc R25 Endodontic file for root canal obturation.
نویسنده
چکیده
منابع مشابه
Comparative evaluation of fracture and defect in reciproc and rotary files in severe curved root canals
Introduction: Root canal instrumentation is an important phase in root canal therapy. Since success in endodontic treatment depends on file defect and fracture, the aim of this study was to compare the evaluation of defect and fracture in rotary and reciproc files in severe curved root canals. Materials & Methods: In this experimental study, 60 mesial canals of human closed apex molars with ...
متن کاملEfficacy of 2 reciprocating systems compared with a rotary retreatment system for gutta-percha removal.
INTRODUCTION The maximum removal of root canal filling material is essential for successful endodontic retreatment. The purpose of this study was to assess the efficacy of 2 reciprocating systems (Reciproc [VDW, Munich, Germany] and WaveOne [Dentsply Maillefer, Ballaigues, Switzerland]) compared with a nickel-titanium (NiTi) rotary system (ProTaper Universal Retreatment [Dentsply Maillefer]) in...
متن کاملDeformation and fracture incidence of Reciproc instruments: a clinical evaluation.
AIM To investigate the incidence of fracture and deformation observed on Reciproc instruments after clinical use. METHODOLOGY A total of 1696 Reciproc NiTi instruments that were discarded after normal clinical usage over 30 months were collected. Of these 1580 instruments were R25 (93%), 76 were R40 (5%), and 40 were R50 (2%). The treatments included 3780 root canal preparations, 3023 primary...
متن کاملMicro-computed tomographic evaluation of canal retreatments performed by undergraduate students using different techniques
Objectives This study evaluated the amount of remaining root canal filling materials after retreatment procedures performed by undergraduate students using manual, rotary, and reciprocating techniques through micro-computed tomographic analysis. The incidence of instrument fracture and the instrumentation time were also evaluated. Materials and Methods Thirty maxillary single rooted teeth wer...
متن کاملCyclic fatigue of Reciproc and WaveOne reciprocating instruments.
AIM To evaluate the cyclic fatigue resistance of Reciproc(®) and WaveOne(®) instruments in simulated root canals. METHODOLOGY Two groups of 15 NiTi endodontic instruments of identical tip size of 0.25 mm were tested, group A; Reciproc(®) R25 and group B: WaveOne(®) primary. Cyclic fatigue testing was performed in a stainless steel artificial canal manufactured by reproducing the instrument's ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- SADJ : journal of the South African Dental Association = tydskrif van die Suid-Afrikaanse Tandheelkundige Vereniging
دوره 69 10 شماره
صفحات -
تاریخ انتشار 2014