The Value of Changing Position in the Detection of CSF Leakage in Spontaneous Intracranial Hypotension Using Tc-99m DTPA Scintigraphy: Two Case Reports
نویسندگان
چکیده
Radionuclide Cisternography (RNC) is of potential value in pointing out the sites of cerebrospinal fluid (CSF) leakage in patients with spontaneous intracranial hypotension (SIH). In the current report, we present two patients who underwent RNC for suspected CSF leakage. Both patients underwent magnetic resonance imaging (MRI) and RNC for evaluation. We describe a simple method to increase the detection ability of RNC for CSF leakage in patients with SIH.
منابع مشابه
Radionuclide Cisternography in Spontaneous Intracranial HypotensionCSF leakage: A Case Report
Received 2/13/2007; revised 4/11/2007; accepted 4/27/2007. For correspondence or reprints contact: Wan-Yu Lin, M.D., Department of Medical Imaging, Taichung Veterans General Hospital. 160 Section 3, Taichung Harbor Road, Taichung 407, Taiwan. Tel: (886)4-23741349, Fax: (886)4-23741348, E-mail: wylin@ vghtc.gov.tw Orthostatic headaches may be caused from spontaneous cerebrospinal fluid (CSF) lea...
متن کاملQuantitative and Qualitative Scintigraphic Measurement of Renal Function in Persian Cat Using 99mTechnetium Ethylenedicysteine and 99mTechnetium Diethylenetriaminepentaacetic
Objective- To consider the use of renal scintigraphic evaluation of kidney function in Persian cat and make a comparison between 99mTechnetium ethylenedicysteine and 99mTechnetium diethylenetriaminepentaacetic in renal scintigraphy. Design- Descriptive study Animals- 6 male healthy adult Persian cats - no clinical sign of renal disorders and prior to presentation. Proce...
متن کاملSpontaneous Intracranial Hypotension Plus Cerebral Venous Thrombosis: A Case Report Study
This is a case study of a 34-year-old woman who was admitted to hospital with a history of severe orthostatic headache. She was diagnosed as having spontaneous intracranial hypotension (SIH) by undetectable cerebrospinal fluid (CSF) pressure at lumbar puncture, and with evidence of diffuse dural enhancement of the brain detected by magnetic resonance imaging (MRI). However, the contrast-enhance...
متن کاملClinical significance of additional lateral imaging in diagnosis of prosthesis infection by combined Tc-99m labeled leukocyte/bone marrow scintigraphy
Introduction: Recently the most accurate diagnostic method in the diagnosis of prosthesis infection is the combination of Tc-99m labeled leukocyte/bone marrow imaging. However the diagnostic efficiency of the test is influenced because of its low spatial resolution. Recently SPECT/CT imaging is implicated in this test with efficient additional diagnostic improvement. In the dep...
متن کاملFalse Negativity of Tc-99m Labeled Sodium Phytate Bone Marrow Imaging Under the Effect of G-CSF Prescription in Aplastic Anemia: A Case Report
Granulocyte colony-stimulating factor (G-CSF) is a hematopoietic cytokine which controls the differentiation and growth of hematopoietic cells in the bone marrow. We report a severe aplastic anemia (SAA) patient with false-negative 99mTc sodium phytate bone marrow imaging findings under concurrent G-CSF therapy. The first bone marrow imaging showed a normal bone marrow activity. However, the bo...
متن کامل