Monte Carlo Calculations Using MCNP4B for an Optimal Shielding Design of a 14-MeV Neutron Source

نویسندگان

  • James C. Liu
  • Tony T. Ng
چکیده

The shielding for 14-MeV neutrons from a D-T generator at SLAC needs to be optimized in terms of shield thickness and cost. Shielding calculations were made using the MCNP4B Monte Carlo code and the ENDF/B-VI cross section set. A few materials were studied: iron, borated polyethylene, three types of normal and heavy concrete, and mixtures of iron and borated polyethylene. The effects of shielding geometry (sphere, cube, and the proposed geometry) were also examined. The transmission results of ambient dose equivalents, as well as the attenuation lengths and the average energies, for neutrons and gammas outside the shielding are presented.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Monte Carlo calculation of shielding parameters for fast neutrons in newly developed heavy concretes

Introduction: The role of radiotherapy as a part of cancer management increases every year around the world. Thus, Radiation protection in the design of radiotherapy rooms are of great importance.   Materials and Methods: In present study using Monte Carlo method, MCNPX code, fourteen types of developed high density concretes with densities ranging from 2.45 ...

متن کامل

Design and Simulation of Photoneutron Source by MCNPX Monte Carlo Code for Boron Neutron Capture Therapy

Introduction Electron linear accelerator (LINAC) can be used for neutron production in Boron Neutron Capture Therapy (BNCT). BNCT is an external radiotherapeutic method for the treatment of some cancers. In this study, Varian 2300 C/D LINAC was simulated as an electron accelerator-based photoneutron source to provide a suitable neutron flux for BNCT. Materials and Methods Photoneutron sources w...

متن کامل

Neutron deep-penetration calculations and shielding design of proton therapy accelerators

Proton therapy accelerators have become increasingly popular for cancer treatment in recent years. In Taiwan, the first proton treatment center equipped with a 235 MeV proton cyclotron in Linkou Chang Gung Memorial Hospital is ready for beam commissioning. Proton therapy accelerators in the energy range could potentially produce intense secondary neutrons, which must be carefully evaluated and ...

متن کامل

The study of neutron interactions with soft tissue using Monte Carlo simulation using the source PF

The most important part of neutron therapy treatment (NCT1) is to achieve a beam of neutrons with suitable energy and intensity, as well as the least pollution and damage. In this study, in order to correct the neutron spectrum from D-D fusion and its use in neutron therapy, a set of different materials which are called the Beam Shaping Assembly (BSA) was placed in the direction of energy 2.45 ...

متن کامل

Optimum shielding structure for the wall of medical LINAC facility

When considering the space limit of high energy LINAC facility in a hospital, the design of shielding wall is strongly required to optimize the wall thickness. Shielding wall usually consists of concrete, and iron plate is sometimes added in concrete to decrease the wall thickness. We investigated the optimum design of the shielding wall in medical LINAC facility by simulation. The calculations...