Assessment of annular distensibility in the aortic valve.

نویسندگان

  • John O'Dea
  • David J Nolan
چکیده

OBJECTIVES The recent introduction of transcatheter aortic heart valves into clinical practice has driven the need to develop methodologies to size such valves without access to the annulus in the manner hitherto possible with open heart surgery. To date, sizing has largely been done according to manufacturer-supplied guidelines based on transoesophageal echocardiography or multidetector computed tomography. We sought to examine how the diameter of the aortic valve annulus stretches under typical pressures encountered in normal and diseased states. In particular, we sought to measure how the area-derived diameter, Dcsa, i.e. the diameter derived from a cross-sectional area, varies with distending pressure. METHODS We conducted testing on 14 explanted pig hearts. Placing each heart in a 37 °C bath, an EndoFLIP EF-325 catheter (Crospon, Galway, Ireland) was introduced into the aortic valve transapically. The catheter allows intra-balloon pressure and up to 16 area-derived diameters to be measured simultaneously, thus permitting the shape of a lumen to be observed. By dividing the minimum area-derived diameter by distending pressure, a measure of distensibility (mm/mmHg) could be determined. Once the balloon was centred, balloon pressure was ramped between 100 and 200 mmHg, and the area-derived diameter was calculated at each pressure. RESULTS Between 100 and 200 mmHg, the mean (SD) increase in diameter was found to be 3.0 (1.5) mm. Distensibility in the different hearts ranged from 0 to 0.05 mm/mmHg. In some cases, the diameter change over the pressure range was negligible, whereas in one case, the diameter change over the range was 5 mm. Whereas different nominal values of diameter are to be expected, a significant variation in the degree of distensibility was observed. CONCLUSIONS Distensibility of the aortic valve annulus is highly variable. Measurement of this parameter in addition to nominal annulus diameter may suggest occasions where a larger transcatheter aortic-valve implantation valve than would be suggested by annulus diameter measurement alone, could be deployed safely with an objective of reducing regurgitation where the annulus is sufficiently distensible.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Correlation Between Aortic Valve Sclerosis and Coronary Artery Disease: A Cross - Sectional Study

  Introduction: Aortic valve sclerosisis considered as a manifestation of coronary atherosclerosis. Recent studies demonstrated an association between aortic valve sclerosis and obstructive coronary artery disease. The purpose of this study was to evaluatethe correlation betweenaortic valve sclerosis andobstructive coronary artery disease and the extent of coronary artery disease in patients ho...

متن کامل

Bicuspid Aortic Valve: An Unusual Cause of Aneurysm of Left Coronary Sinus of Valsalva

Bicuspid aortic valve is traditionally considered an innocuous congenital anomaly. Due to a better and widespread availability of non-invasive imaging techniques, it has come to the fore that 30% of these cases develop complications, viz., valve abnormality (aortic regurgitation and stenosis), and aneurysm of aortic root and ascending aorta. Sinus of Valsalva aneurysm is an uncommon complicatio...

متن کامل

بررسی میزان اتساع پذیری آئورت توراسیک و ارتباط آن با پلاکهای آترواسکلروتیک آئورت و عروق کورونری: مطالعه‌ای چند مرکزی با استفاده از دستگاههای توموگرافی کامپیوتری 64 مقطعی و 256 مقطعی

Background and Aim: Despite previously shown relationship between the aortic atherosclerosis and coronary artery disease, the relationship between aortic distensibility and the presence, extent and composition of thoracic aortic plaques (TAP) is not widely assessed. We evaluated the relationship between aortic distensibility and the presence, extent and composition of TAP in current research. ...

متن کامل

Vortex and Oil Distribution of Oil-Water Annular Flow through Ball Valve

The study on the flow behave inside of a ball valve is important for heavy crude oil transportation. Owe to the fast progress of the numerical technique, it becomes an effective way to observe the flows inside a valve and to analyze the flow structure of the oil-water core annular flow. In the present study, the simulation of the oil-water core annular flowing through the valve is conducted...

متن کامل

Assessment of aortic stiffness by cardiovascular magnetic resonance following the treatment of severe aortic stenosis by TAVI and surgical AVR

BACKGROUND Aortic stiffness is increasingly used as an independent predictor of adverse cardiovascular outcomes. We sought to compare the impact of transcatheter aortic valve implantation (TAVI) and surgical aortic valve replacement (SAVR) upon aortic vascular function using cardiovascular magnetic resonance (CMR) measurements of aortic distensibility and pulse wave velocity (PWV). METHODS AN...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Interactive cardiovascular and thoracic surgery

دوره 15 3  شماره 

صفحات  -

تاریخ انتشار 2012