Sirolimus-eluting stents suppress neointimal formation irrespective of metallic allergy.
نویسندگان
چکیده
BACKGROUND Metallic allergy is associated with restenosis following bare metal stent implantation, but the impact of metallic allergy on the outcome after implantation of drug-eluting stents (DES) has not been investigated. METHODS AND RESULTS The present study group consisted of 88 consecutive patients (109 lesions) who underwent percutaneous coronary intervention with sirolimus-eluting stents (SES). Follow-up angiography was obtained at 8 months in all patients. At that time, the patients underwent epicutaneous patch tests for nickel, chromate, molybdenum, manganese, and titanium, which were evaluated after 48 h of contact. The patch test was positive in 14 patients (16%) (5 for manganese, 3 for nickel, 1 for chromate, 1 for Nickel and manganese, and 4 for manganese and chromate). The binary restenosis rate in the patients with a positive patch test was similar to those with negative patch test (6.3% vs 6.5%, p=0.98). Serial quantitative coronary angiography analyses identified no significant differences in late lumen loss of in-stent segments between patients with positive patch test and those with negative patch test (0.19+/-0.49 mm vs 0.12+/-0.48 mm, p=0.55). CONCLUSION SES prevent restenosis irrespective of metallic allergy. The classic relationship between metallic allergy and in-stent restenosis, seen with bare metal stents, does not appear to arise with DES, possibly because of the immunosuppressive effect of sirolimus.
منابع مشابه
Nanoporous CREG-Eluting Stent Attenuates In-Stent Neointimal Formation in Porcine Coronary Arteries
BACKGROUND The goal of this study was to evaluate the efficacy of a nanoporous CREG-eluting stent (CREGES) in inhibiting neointimal formation in a porcine coronary model. METHODS In vitro proliferation assays were performed using isolated human endothelial and smooth muscle cells to investigate the cell-specific pharmacokinetic effects of CREG and sirolimus. We implanted CREGES, control sirol...
متن کاملDrug-eluting stent update 2007: part I. A survey of current and future generation drug-eluting stents: meaningful advances or more of the same?
Analyst projections for the drug-eluting stent (DES) market estimated that the total number of DES implanted in 2010 would go beyond 4.5 million worldwide. Although the initial results seemed promising, longer-term follow-up in a broader range of patients revealed some pitfalls. Delayed neointimal growth, enhanced platelet aggregation, a local hypersensitivity reaction against the polymer coati...
متن کاملPart I: A Survey of Current and Future Generation Drug-Eluting Stents: Meaningful Advances or More of the Same?
Analyst projections for the drug-eluting stent (DES) market estimated that the total number of DES implanted in 2010 would go beyond 4.5 million worldwide. Although the initial results seemed promising, longer-term follow-up in a broader range of patients revealed some pitfalls. Delayed neointimal growth, enhanced platelet aggregation, a local hypersensitivity reaction against the polymer coati...
متن کاملAngioscopic Evaluation of Neointimal Coverage of Coronary Stents
Drug-eluting stents (DES) reduce coronary restenosis significantly; however, late stent thrombosis (LST) occurs, which requires long-term antiplatelet therapy. Angioscopic grading of neointimal coverage of coronary stent struts was established, and it was revealed that neointimal formation is incomplete and prevalence of LST is higher in DES when compared to bare-metal stents. It was also obser...
متن کاملHistological validation of frequency domain optical coherence tomography for the evaluation of neointimal formation after a novel polymer-free sirolimus-eluting stent implantation.
Novel polymer-free drug-eluting stents have been developed to reduce polymer-related adverse events. However, neointimal coverage after polymer-free DES implantation is unclear and validation between optical coherence tomography (OCT) and histology is required. Sixteen polymer-free sirolimus-eluting stents were randomly implanted into coronary arteries of 8 normal swine. OCT and histological me...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation journal : official journal of the Japanese Circulation Society
دوره 72 6 شماره
صفحات -
تاریخ انتشار 2008