Histologic evaluation of a 9-year-old hydroxyapatite-coated cylindric implant placed in conjunction with a subantral augmentation procedure: a case report.

نویسندگان

  • P Proussaefs
  • J Lozada
چکیده

The histologic examination of dental implants retrieved from humans provides a unique opportunity to evaluate the bone-implant interface. This case report presents a clinical, radiographic, and histologic evaluation of a cylindrical hydroxyapatite- (HA) coated implant retrieved from the posterior maxillary area of a patient after 9 years after placement. The implant had been placed in conjunction with a subantral augmentation procedure with HA as the graft material. Clinical examination revealed an immobile implant with no sign of pathosis. Radiographic examination indicated close proximity of the bone to the implant surface without evidence of radiolucency. Histologically, because of tissue destruction during implant retrieval, only the apical portion of the implant was available for examination under light microscopy, and it appeared to be integrated with the surrounding bone; 45.9% of the surface of the implant had close bone apposition at the interface. There was no evidence of dissolution of the HA coating and the bone appeared to be in immediate contact with the coating. Residual graft particles were present and in close proximity with the implant surface. These observations suggest that the subantral augmentation procedure performed simultaneously with the placement of an HA-coated implant with HA as the graft material apparently resulted in osseointegration between the implant and the surrounding bone. The implant was maintained without complication for 9 years.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Histologic evaluation of a 12-year-old threaded hydroxyapatite-coated implant placed in conjunction with subantral augmentation procedure: a clinical report.

This clinical report presents a histologic evaluation of a threaded hydroxyapatite-coated root-form implant retrieved from the posterior maxillary area of a patient after being in function for 12 years. The implant had been placed in conjunction with subantral augmentation. Histologically, the portion of the implant that was examined under light microscopy appeared to be integrated with the sur...

متن کامل

Management of a Congenitally Missing Lateral Incisor with Orthodontics, Bone Grafting (a New Method) and Single-Tooth Implant: A Case Report

Careful treatment planning, space management, augmentation of bone and attention to the details of implant surgical and prosthetic techniques are important factors when treating anterior maxilla specially replacement of missing teeth. This case report addresses a chair-side ridge augmentation procedure using autograft bone harvested with trephine drills and placed without using screws and the f...

متن کامل

The use of orthodontic treatment and immediate implant loading to restore the traumatic loss of a maxillary central incisor.

This clinical case describes a new orthodontic/surgical concept for immediate loading of hydroxyapatite-coated cylindric implants, placed at the end of orthodontic treatment, to restore a traumatically lost maxillary central incisor. Further clinical and histologic studies are necessary to promote routine clinical application of this technique.

متن کامل

Prospective study of 429 hydroxyapatite-coated cylindric omniloc implants placed in 121 patients.

PURPOSE Controversy over the long-term clinical effectiveness of hydroxyapatite (HA)-coated dental implants still persists, despite numerous clinical studies documenting high survival rates. The Ohio State University College of Dentistry undertook a 5-year prospective study of 429 HA-coated cylindric implants placed into 121 patients to determine the long-term clinical performance of the implan...

متن کامل

Sinus augmentation for single-tooth replacement in the posterior maxilla: a 3-year follow-up clinical report.

A technique for single-tooth sinus lift and simultaneous implant placement in the posterior maxilla is presented. Ten hydroxyapatite-coated cylindric implants, 13 to 15 mm in length, were placed together with a composite bone graft of demineralized freeze-dried bone allograft and autogenous bone in 10 adults. Surgical technique and anatomic considerations are discussed. Follow-up of 3 years sho...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The International journal of oral & maxillofacial implants

دوره 16 5  شماره 

صفحات  -

تاریخ انتشار 2001