Comparison between tripod and skin-fixed recording of scapular motion.
نویسندگان
چکیده
Non-invasive dynamical measurements of 3D scapular motion can be performed easily by attachment of a 6 DOF electromagnetic receiver onto the skin above the acromion. To quantify the introduction of possible errors due to skin displacement, we assessed 3D scapular positions on n=8 subjects by both tripod and skin-fixed method. Error analysis included the variables method (tripod, skin-fixed simultaneously with tripod, separate skin-fixed at 0 and 0.25Hz of elevation speed), plane of elevation (0 degrees and 90 degrees ) and observation (receiver replacement: n=3). Inter-individual 'group' differences depended on elevation plane and showed an average underestimation of scapular rotation of 6.5 degrees (worst case 13 degrees ) using the skin-fixed method. Only the group RMSE, not the individual RMSE, could be successfully lowered using linear regression (to about 2 degrees ). Inter-trial reliability (RMSE <3.24 degrees , ICC>0.94) and RMSE between 0 and 0.25Hz recordings (about 2.5 degrees ) were satisfactory. Intra-observer RMSE after replacement of the skin-fixed receiver was 5 degrees . The skin-fixed method is suitable for dynamic recordings of scapular rotations; however, measurements are precise only when the acromion receiver is not replaced. Combined with a relatively low accuracy, we conclude that the skin-fixed method should be used only in combination with tripod 'calibration'.
منابع مشابه
Skin-fixed scapula trackers: a comparison of two dynamic methods across a range of calibration positions.
The aim of this study was to establish the optimal methodology for skin-fixed measurement of the scapula during dynamic movement. This was achieved by comparing an optimally positioned Scapula Tracker device (ST) to a previously described palpation device, taken as the true measure of scapular kinematics. These measurements were compared across a range of calibration positions, including the us...
متن کاملComparison of the Effect of Codman Exercises and Scapular Rhythm on Pain and External Rotation of Shoulder in Women with Frozen Shoulder Syndrome
Introduction: Frozen shoulder syndrome (FSS) is a common shoulder disease that causes pain and has progressive loss of shoulder motion. Codman's pendulum exercises are commonly prescribed after a shoulder injury to provide early joint mobilization, increase the flow of nutrients into the joint space, and decrease pain. This study aimed to compare the effect of Cadman's exercises and scapular rh...
متن کاملEffect of eight weeks of scapular-focused exercise with and without feedback on pain, function, and scapular kinematic in a participant with shoulder impingement syndrome
Background and Aim: This study aimed to evaluate the effects of scapular-focused treatment with (SFTF) and without (SFT) feedback on pain, function, and scapular kinematics in patients with Shoulder Impingement Syndrome (SIS). Materials and Methods: 36 males and females with SIS (age of 37 ± 6.3 years) were randomly assigned into SFTF (n=12), SFT (n=12) and control (n=12) groups. The primary o...
متن کاملBRADY L . TRIPP , MEd , ATC , and TIM L . UHL , PhD , ATC , PT • University of Kentucky Clinical Assessment of Scapular Motion
© 2003 Human Kinetics • ATT 8(5), pp. 20-24 Many athletic therapists appreciate the role that scapular function plays in maintaining the integrity of the shoulder and therefore include its assessment in their comprehensive shoulder evaluation. A clinician’s observation might result in a determination of pathology called scapular dyskinesis, indicating the presence of abnormal scapular motion or...
متن کاملDynamic measurements of three-dimensional scapular kinematics: a validation study.
The validation of two noninvasive methods for measuring the dynamic three-dimensional kinematics of the human scapula with a magnetic tracking device is presented. One method consists of simply fixing a sensor directly to the acromion and the other consists of mounting a sensor to an adjustable plastic jig that fits over the scapular spine and acromion. The concurrent validity of both methods w...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of biomechanics
دوره 40 4 شماره
صفحات -
تاریخ انتشار 2007