Interobserver and intraobserver reliability of a classification scheme for corneal topographic patterns.

نویسندگان

  • K Rasheed
  • Y S Rabinowitz
  • D Remba
  • M J Remba
چکیده

AIMS To determine the interobserver and the intraobserver reliability of a published classification scheme for corneal topography in normal subjects using the absolute scale. METHOD A prospective observational study was done in which 195 TMS-1 corneal topography maps in the absolute scale were independently classified twice by three classifiers--a cornea fellow, an ophthalmic technician, and an optometrist. From these observations the interobserver reliability for each category and the intraobserver reliability for each observer were determined in terms of the median weighted kappa statistic for each category and for each observer. RESULTS For interobserver reliability, the median weighted kappa statistic for each category varied from 0.72 to 0.97 and for intraobserver reliability the range was 0.79 to 0.98. CONCLUSION This classification scheme is extremely robust and even in the hands of less experienced observers with minimal training it can be relied upon to provide consistent results.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The interobserver and intraobserver reliability of the Fernandez classification of distal radius fracture

 Abstract Background: With increasing knowledge concerning fractures of the distal radius, different classifications have been proposed. Reliability of most of these classifications has been assessed. The Fernandez classification has never been assessed for intraobserver and interobserver reliability, although this classification is commonly used. Methods: Five observers including one attending...

متن کامل

Reliability of classification systems for subaxial cervical injuries

STUDY DESIGN  Interobserver and intraobserver reliabilityObjective: To measure and compare the interobserver and intraobserver reliability of the cervical spine injury severity score (CSISS), the subaxial injury classification (SLIC) and severity scale, and the Allen-Ferguson system in patients with subaxial cervical spine injuries presenting to the emergency department. METHODS  Five examine...

متن کامل

ارزیابی پایایی درون مشاهده گر و میان مشاهده گر در طبقه بندی یانگ و برگس برای شکستگی های لگن

Background: Determination of interobserver and intraobserver reliability are one of the most important issue in educations with are necessary for validation of classifications. Methods: Radiographies and CT scans of 160 patients were assessed by three orthopedics to determination of the anatomic location of fractures and to determine classification of fractures according to Young and Burgess c...

متن کامل

The interobserver and intraobserver reliability of the Fernandez clas- sification of distal radius fracture

Background: With increasing knowledge concerning fractures of the distal radius, different classifications have been proposed. Reliability of most of these classifications has been assessed. The Fernandez classification has never been assessed for intraobserver and interobserver reliability, although this classification is commonly used. Methods: Five observers including one attending orthopaed...

متن کامل

Inter- and intraobserver reliability of the MTM-classification for proximal humeral fractures: A prospective study

BACKGROUND A precise modular topographic-morphological (MTM) classification for proximal humeral fractures may address current classification problems. The classification was developed to evaluate whether a very detailed classification exceeding the analysis of fractured parts may be a valuable tool. METHODS Three observers classified plain radiographs of 22 fractures using both a simple vers...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The British journal of ophthalmology

دوره 82 12  شماره 

صفحات  -

تاریخ انتشار 1998