Superresolution optical system by common-path interferometry.

نویسندگان

  • Vicente Mico
  • Zeev Zalevsky
  • Javier García
چکیده

We present a new approach to obtain superresolved images in digital holography by means of synthetic aperture generation using common-path interferometry and off-axis illumination in optical imaging systems. The paper includes two parts. First, we present a simple approach to double the resolution of an optical system using tilted illumination onto the object and an optical element in the image plane to produce the holographic recording. Then we present a novel approach consisting of attaching a diffraction grating in parallel together with the object in the input plane and using off-axis illumination provided by a Vertical Cavity Surface Emitting Lasers (VCSEL) array to allow us achieving a major improvement in the optical resolution limit with an extremely low penalty in the complexity of the resulting system. Experimental investigation based on commercial microscope objectives is presented.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

0 Interstellar Seeing . I . Superresolution Techniques Using Radio Scintillations

Interstellar scintillation can be used to probe transverse sizes of radio sources on scales inaccessible to the nominal resolution of any terrestrial telescope, e.g. ∼< 10−6 arc sec. Methodology is presented that exploits this superresolution phenomenon for both single aperture and interferometer observations. The treatment applies to the saturated (strong-scattering) regime and holds for both ...

متن کامل

Optical Path Stability and Fringe Tracking in Optical Stellar Interferometry

In this paper we analyze the problems of fringe pattern estimation in optical stellar interferometry that are associated with optical path errors. Our rst nding is that an optimal fringe tracking system must track with path length errors of less than about one-eighth of the coherence length. The second is that if phase closure estimation is to be achieved at the lowest possible light levels, th...

متن کامل

Improved common-path optical heterodyne interferometer for measuring small optical rotation angle of chiral medium

An improved common-path optical heterodyne interferometry for measuring small optical rotation angle of chiral liquid is presented. The optical rotation angle can be determined by the phase difference between the test and reference signals. By means of inserting a phase retarder behind the test sample, the measuring resolution of optical rotation angle is greatly enhanced. The theoretical predi...

متن کامل

Optical resolution below λ/4 using synthetic aperture microscopy and evanescent-wave illumination

Evanescent-wave illumination is applied to synthetic-aperture microscopy on a transparent solid substrate to extend the resolution limit to λ/2(n+1) (where n is the substrate refractive index) independent of the lens NA. Using a 633 nm source and a 0.4 NA lens, a resolution to 150 nm (λ/4.2) is demonstrated on a glass (n = 1.5) substrate. Further extension to ~ 74-nm resolution (λ/8.6) is proje...

متن کامل

Common-path interferometric detection of protein monolayer on the BioCD.

The bio-optical compact disk (BioCD) is an optical biosensor that performs common-path molecular interferometry of patterned proteins on a disk spinning at high speed. The common-path configuration makes it ultrastable and allows surface height precision below 10 pm. In this paper we show that two complementary interferometric quadrature conditions exist simultaneously that convert the modulus ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Optics express

دوره 14 12  شماره 

صفحات  -

تاریخ انتشار 2006