Effects of recycling on the biomechanical characteristics of retrieved orthodontic miniscrews
نویسندگان
چکیده
OBJECTIVE The aim of this study was to compare recycled and unused orthodontic miniscrews to determine the feasibility of reuse. The comparisons included both miniscrews with machined surfaces (MS), and those with etched surfaces (ES). METHODS Retrieved MS and ES were further divided into three subgroups according to the assigned recycling procedure: group A, air-water spray; group B, mechanical cleaning; and group C, mechanical and chemical cleaning. Unused screws were used as controls. Scanning electron microscopy, energy-dispersive X-ray spectrometry, insertion time and maximum insertion torque measurements in artificial bone, and biological responses in the form of periotest values (PTV), bone-implant contact ratio (BIC), and bone volume ratio (BV) were assessed. RESULTS Morphological changes after recycling mainly occurred at the screw tip, and the cortical bone penetration success rate of recycled screws was lower than that of unused screws. Retrieved ES needed more thorough cleaning than retrieved MS to produce a surface composition similar to that of unused screws. There were no significant differences in PTV or BIC between recycled and unused screws, while the BV of the former was significantly lower than that of the latter (p < 0.05). CONCLUSIONS These results indicate that reuse of recycled orthodontic miniscrews may not be feasible from the biomechanical aspect.
منابع مشابه
Biomechanical Effects of Various Bone-Implant Interfaces on the Stability of Orthodontic Miniscrews: A Finite Element Study
INTRODUCTION Osseointegration is required for prosthetic implant, but the various bone-implant interfaces of orthodontic miniscrews would be a great interest for the orthodontist. There is no clear consensus regarding the minimum amount of bone-implant osseointegration required for a stable miniscrew. The objective of this study was to investigate the influence of different bone-implant interfa...
متن کاملEnhanced compatibility and initial stability of Ti6Al4V alloy orthodontic miniscrews subjected to anodization, cyclic precalcification, and heat treatment
OBJECTIVE To evaluate the bioactivity, and the biomechanical and bone-regenerative properties of Ti6Al4V miniscrews subjected to anodization, cyclic precalcification, and heat treatment (APH treatment) and their potential clinical use. METHODS The surfaces of Ti6Al4V alloys were modified by APH treatment. Bioactivity was assessed after immersion in simulated body fluid for 3 days. The hydroph...
متن کاملThread Pitch Variant in Orthodontic Mini-screws: A 3-D Finite Element Analysis
Orthodontic miniscrews are widely used as temporary anchorage devices to facilitate orthodontic movements. Miniscrew loosening is a common problem, which usually occurs during the first two weeks of treatment. Macrodesign can affect the stability of a miniscrew by changing its diameter, length, thread pitch, thread shape, tapering angle and so on. In this study, a 3-D finite element analysis wa...
متن کاملMiniscrews for orthodontic anchorage: nanoscale chemical surface analyses.
OBJECTIVES The goal of this study was to determine the chemical composition of the passivation layer of three clinically available orthodontic miniscrews at different depths. MATERIALS AND METHODS The miniscrews used were Aarhus Mini-Implant (AAR), IMTEC Ortho (IMT), and VectorTAS (VEC). The chemical compositions of the as-received miniscrews were determined by X-ray photoelectron spectroscop...
متن کاملMiniscrew appliances and their use in orthodontics
Anchorage is an important factor in orthodontics and must be properly managed for a successful treatment outcome. Orthodontists have historically used many devices to prevent unwanted tooth movement. The use of miniscrews as a source of skeletal anchorage has become routine in present-day orthodontic practice. Skeletal anchorage opens up alternative treatments, to borderline surgery patients fo...