Prospective, Randomized, Multicenter Evaluation of a Polyethylene Terephthalate Micronet Mesh-Covered Stent (MGuard) in ST-Segment Elevation Myocardial Infarction: The MASTER Trial.

نویسندگان

  • Gregg W Stone
  • Alexandre Abizaid
  • Sigmund Silber
  • Jose M Dizon
  • Béla Merkely
  • Ricardo A Costa
  • Ran Kornowski
  • Andrea Abizaid
  • Roman Wojdyła
  • Akiko Maehara
  • Ovidiu Dressler
  • Sorin J Brener
  • Eli Bar
  • Dariusz Dudek
چکیده

OBJECTIVES This study sought to evaluate the potential utility of a novel polyethylene terephthalate micronet mesh-covered stent (MGuard) in patients with acute ST-segment elevation myocardial infarction (STEMI) undergoing percutaneous coronary intervention (PCI). BACKGROUND Suboptimal myocardial reperfusion after PCI in STEMI is common and results in increased infarct size and mortality. The MGuard is a novel thin-strut metal stent with a polyethylene terephthalate micronet covering designed to trap and exclude thrombus and friable atheromatous debris to prevent distal embolization. METHODS A total of 433 patients with STEMI presenting within 12 h of symptom onset undergoing PCI were randomized at 50 sites in 9 countries to the MGuard (n = 217) or commercially available bare metal or drug-eluting stents (n = 216). The primary endpoint was the rate of complete (≥70%) ST-segment resolution measured 60 to 90 min post-procedure. RESULTS Baseline characteristics were well matched between the groups. The primary endpoint of post-procedure complete ST-segment resolution was significantly improved in patients randomized to the MGuard stent compared with control patients (57.8% vs. 44.7%; difference: 13.2%; 95% confidence interval: 3.1% to 23.3%; p = 0.008). By core laboratory analysis, the MGuard stent compared with control stents also resulted in superior rates of Thrombolysis In Myocardial Infarction 3 flow (91.7% vs. 82.9%, p = 0.006) with comparable rates of myocardial blush grade 2 or 3 (83.9% vs. 84.7%, p = 0.81). Mortality (0% vs. 1.9%, p = 0.06) and major adverse cardiac events (1.8% vs. 2.3%, p = 0.75) at 30 days were not significantly different between patients randomized to the MGuard stent and control stent, respectively. CONCLUSIONS Among patients with acute STEMI undergoing emergent PCI, the MGuard micronet mesh-covered stent compared with conventional metal stents resulted in superior rates of epicardial coronary flow and complete ST-segment resolution. A larger randomized trial is warranted to determine whether these benefits result in reduced infarct size and/or improved clinical outcomes. (Safety and Efficacy Study of MGuard Stent After a Heart Attack [MASTER]; NCT01368471).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Mesh-covered embolic protection stent implantation in ST-segment-elevation myocardial infarction: final 1-year clinical and angiographic results from the MGUARD for acute ST elevation reperfusion trial.

BACKGROUND The MGuard, a bare metal stent covered with a polymer mesh, was designed to reduce distal embolization during percutaneous coronary intervention in ST-segment-elevation myocardial infarction. In the MGUARD for Acute ST Elevation Reperfusion trial, the primary end point of complete ST-segment resolution was significantly improved with the MGuard compared with control. We evaluated 1-y...

متن کامل

Thrombus entrapment by a novel mesh-covered stent in ST-segment elevation myocardial infarction.

AIMS The MGuard stent (bare metal stent wrapped externally with a polymer mesh sleeve) is designed to prevent distal embolisation by reducing thrombus and plaque fragments released during and post percutaneous coronary intervention (PCI). The aim of this study was to confirm the clinical feasibility, safety and performance of the MGuard stent during primary PCI for ST-segment elevation myocardi...

متن کامل

MGuardTM stent... We beg to differ. Commentary to the article "Long-term follow-up of mesh-covered stent implantation in patients with ST-segment elevation myocardial infarction".

BACKGROUND The MGuard stent (a bare-metal stent wrapped externally in a polymer mesh sleeve) was introduced to reduce the risk of distal embolisation and no-reflow phenomenon during percutaneous coronary intervention (PCI) in thrombus containing lesions, including ST-segment elevation myocardial infarction (STEMI). However, data on the long-term performance of the MGuard stent is limited. AIM...

متن کامل

Efficacy of an Embolic Protection Stent as a Function of Delay to Reperfusion in ST-Segment Elevation Myocardial Infarction (from the MASTER Trial).

The ability of stent implantation to improve indexes of reperfusion may depend on the time to reperfusion in acute ST-segment elevation myocardial infarction (STEMI) and may also vary with stent type. The purpose of this prespecified analysis from the randomized MGUARD for Acute ST Elevation Reperfusion trial was to evaluate the impact of delay to reperfusion on outcomes in patients with STEMI ...

متن کامل

The effect of oxygen inhalation on cardiac biomarkers in patients presenting with acute ST-segment elevation myocardial infraction: A randomized clinical trial

Background: It is assumed giving oxygen to patients with acute myocardial infraction may increase the oxygenation of the ischemic tissue; however, the usefulness of oxygen in these patients has become a challenging topic. Thus, the present study aimed to determine the effect of oxygen inhalation on cardiac biomarkers in patients with acute myocardial infarction.    Methods: This randomized cli...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American College of Cardiology

دوره 60 19  شماره 

صفحات  -

تاریخ انتشار 2012