Evaluation of bleb characteristics after implantation of the EX-PRESS™ glaucoma filtration device
نویسندگان
چکیده
PURPOSE To compare bleb survival and histology after implantation of the EX-PRESS™ glaucoma filtration device versus silicone tubes in a rabbit model of filtration surgery. METHODS Glaucoma filtration surgery was performed on one eye each of twelve New Zealand white rabbits. Eyes were randomized to implantation with the EX-PRESS™ filtration device (n=6) or a silicone tube (n=6). Bleb vascularity was evaluated at three and six weeks using a standard scale. At 6 weeks, eyes were enucleated and a histologic analysis was performed. Bleb survival was also recorded for the two groups. RESULTS Histologically, a thin capsule consisting of mild fibroblast proliferation associated with intercellular collagen was present around both implants. Both groups demonstrated a mild infiltration of plasma cells and polymorphonuclear leukocytes. Bleb vascularity was similar between both groups at three and six weeks post-operatively. Bleb survival between the two groups was not significantly different. CONCLUSIONS Similar outcomes were noted after glaucoma filtration surgery using either silicone tubes or the EX-PRESS™ glaucoma filtration device in this rabbit model. Both implants appear to be relatively inert with little difference in biocompatibility and bleb survival.
منابع مشابه
Ex-PRESS Glaucoma Filtration Device: Theory, Technique and Results
The Ex-PRESS glaucoma filtration device (Alcon Laboratories, Fort Worth, TX , USA) is designed to drain aqueous fluid from the anterior chamber to the subconjunctival space and form a filtration bleb, akin to a trabeculectomy. In this article we will review the surgical indications, preoperative evaluation, surgical techniques and postoperative considerations of this ophthalmic device. J Emmetr...
متن کاملEX-PRESS Glaucoma Filtration Device: efficacy, safety, and predictability
Trabeculectomy has been the traditional primary surgical therapy for open-angle glaucoma. While trabeculectomy is effective in lowering intraocular pressure, complications associated with the procedure have motivated the development of alternative techniques and devices, including the EX-PRESS Glaucoma Filtration Device. This review describes the efficacy, safety, complication rates, and potent...
متن کاملFive-year extension of a clinical trial comparing the EX-PRESS glaucoma filtration device and trabeculectomy in primary open-angle glaucoma
BACKGROUND This study compared the efficacy of the EX-PRESS(®) glaucoma filtration device and trabeculectomy in primary open-angle glaucoma up to five years after surgery. METHODS Patients from a previously reported randomized, open-label, parallel-arm clinical trial in which 78 patients received either the EX-PRESS glaucoma filtration device or underwent a trabeculectomy were followed for up...
متن کاملTwo Cases of Suprachoroidal Hemorrhage after Implantation of an Ex-Press Miniature Glaucoma Device and an Intraocular Lens
Suprachoroidal hemorrhage is a rare complication of ophthalmic surgery in general and of glaucoma filtration procedures in particular. We present herein two cases of suprachoroidal hemorrhage in aphakic patients after simultaneous implantation of an Ex-Press miniature glaucoma device and an intraocular lens. Although a rare complication, we have now seen two cases develop in previously aphakic ...
متن کاملA case report of progressive obstruction of Ex-PRESS miniature glaucoma shunt after transient flat anterior chamber and treatment using Nd:YAG laser
BACKGROUND We report a case of Ex-PRESS miniature glaucoma shunt obstruction resulting from progressive iris synechial formation after transient anterior chamber shallowing. CASE PRESENTATION A 68-year-old woman with pseudoexfoliation glaucoma in her right eye underwent filtration surgery with implantation of the Ex-PPESS shunt (model P-50, Alcon Japan, Tokyo, Japan) in combination with intra...