Field calibration of the glass-based retrospective radon detectors for epidemiologic applications

نویسنده

  • Kainan Sun
چکیده

The primary goal of this PhD research was to obtain critical information needed to further calibrate the novel glass-based retrospective radon detectors (RRDs) by characterizing the quantitative relationship between radon gas concentrations, the surface-deposited activities of various radon progeny, the airborne dose rate, and various residential environmental factors through both actual field measurements and MonteCarlo simulation. Radon and radon progeny concentrations were measured, from May 2005 to May 2007, in 38 Iowa houses occupied by either smokers or nonsmokers. The investigation took into account several important indoor environmental factors, which have crucial influences on the radon progeny deposition process in homes. The long-term (3 months) surface-deposited radon progeny by species and implanted Po were measured using a RRD. During the 3 months, the short-term (3-7 days) airborne radon progeny by species and bimodal size fraction were measured using a recently developed active detector. Both passive and active detectors are solid state nuclear track detectors. Airborne dose rates were calculated from unattached and attached potential alpha energy concentrations (PAECs) based on both Porstendörfer’s effective dose conversion factor and that of James. Correlation analysis and multiple linear regression analysis were applied to analyze both field study results and Monte-Carlo simulation study results. Temporal and spatial variations among airborne dose rates and surface-deposited radon progeny were also investigated in actual field settings. Overall, deposited radon progeny were useful in predicting airborne dose rate in addition to the radon gas concentration. The occurrence of smoking was the most crucial environmental factor influencing the deposition process. In addition, other environmental factors were identified that served as useful covariates predicting airborne dose rates by smoking status.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Intercomparison of retrospective radon detectors.

We performed both a laboratory and a field intercomparison of two novel glass-based retrospective radon detectors previously used in major radon case-control studies performed in Missouri and Iowa. The new detectors estimate retrospective residential radon exposure from the accumulation of a long-lived radon decay product, (210)Pb, in glass. The detectors use track registration material in dire...

متن کامل

Potential for bias in epidemiologic studies that rely on glass-based retrospective assessment of radon.

Retrospective assessment of exposure to radon remains the greatest challenge in epidemiologic efforts to assess lung cancer risk associated with residential exposure. An innovative technique based on measurement of alpha-emitting, long-lived daughters embedded by recoil into household glass may one day provide improved radon dosimetry. Particulate air pollution is known, however, to retard the ...

متن کامل

Measurement of Contemporary and Retrospective Radon Concentration in Ramsar Dwellings Using Polycarbonate Detector

The origins of radon gas are the amount of uranium decay in the soil that is released into space and through the interior gaps of  buildings. Radon can enter the respiratory system and cause radiation hazards. Recently research has identified Radon as the second leading cause of lung cancer after cigarette smoking. The indoor concentration of Radon progeny is mentioned as an important issue reg...

متن کامل

Calibration and optimization of a low cost diffusion chamber for passive separated measurements of radon and thoron in soil by Lexan PC SSNTD

Background: Separate radon and thoron measurements in soil are very important in assessment of internal exposure due to inhalation of such radioactive gases. Materials and Methods: In this study, a low cost, small size, passive diffusion chamber has been developed for simple measurement of Radon-222 and Radon-220(Thoron) gases separately in soil. The diffusion chamber consists of two films and ...

متن کامل

A further study of the (CR–LR) difference technique for retrospective radon exposure assessment

The (CR–LR) difference technique, based on the CR-39 and LR 115 detectors, for the determination of implanted Po in glass after deposition of short-lived radon progeny, was analyzed in details in this paper. The sensitivities of both detectors were calculated using the Monte Carlo method with V functions particularly derived in our previous works for the detectors used in the present experiment...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015