A Heuristic Supply Air Temperature Reset Strategy for VAV Systems Employing Variable-Capacity DX Cooling Equipment
نویسندگان
چکیده
This paper presents a generalized control heuristic to reset supply air temperature setpoints for DX units with capacity modulation and variable air flow. The heuristic is shown to work well for different DX systems with different compressor types and fan-duct combinations. Digital scroll and variable-speed compressors were considered and modeled using curve fits to manufacturer’s data. Evaporator and condenser models were also constructed using the catalog data of a representative split DX cooling system. The component models were coupled to provide an overall performance map for each DX system. Fan power is another critical portion of the total HVAC power consumption. In this study, a simple method was used to characterize the performance of a duct system based on typical relationships between pressure drop and air flow rate. Different duct characteristics were coupled to different types of supply fans to provide a set of fan power maps. Optimization was then performed for each combination to find the optimal supply air temperature that minimizes total fan and compressor power. This provided a baseline for developing and validating results of the heuristic control strategy. To assess the integrated energy savings potential of the heuristic strategy, a simulation platform was developed for a medium sized commercial building. Simulations were carried out for a 100-day cooling season in different U.S. locations and under different control strategies, including a conventional control with a constant supply air temperature setpoint and the heuristic reset strategy. It is shown that the heuristic control can provide significant cost savings relative to conventional control depending on the system type and location.
منابع مشابه
Impacts of Static Pressure Reset on VAV System Air Leakage, Fan Power and Thermal Energy ───Part I: Theoretical Model and Simulation
As for a variable air volume (VAV) system, the air duct static pressure is a typical control variable maintained by modulating supply fan speed. The static pressure equals to the summation of the duct pressure loss downstream of the sensor to the terminal box and box inlet static pressure. Typically, the air duct static pressure is set as a constant set point based on the system design informat...
متن کاملEnergy Efficiency and the Control and Simulation of VAV Systems
Variable air volume (VAV) systems are one of the most common air-conditioning system types for larger buildings in warm temperate climates and are likely to remain so for some time. However, VAV systems are heavily dependent upon control for their efficient operation and are particularly prone to system-wide failure as a result of the malfunction of individual components in the field. In this p...
متن کاملUnderstanding Single-Zone VAV Systems
c Traditionally, single-zone VAV has been used for larger, densely occupied zones that have variable cooling loads. Common examples include gymnasiums, cafeterias, lecture halls, auditoriums, large meeting rooms, churches, and arenas. Therefore, it has been available primarily in larger airhandling units and large, packaged rooftop equipment. This type of equipment has long been available with ...
متن کاملMechanical Ventilation and Equipment
Mechanical ventilation systems for controlling conditions in individual zones can move a constant or variable supply of conditioned air to handle all or some of the heating and cooling loads. They are classified as all-air, air-water, and all-water systems. All-air systems include single-duct, dual-duct and multizone. The systems can be designed to operate at Constant Air Volume (CAV) or Variab...
متن کاملA PD Law Based Fuzzy Logic Control Strategy For Simultaneous Control Of Indoor Temperature And Humidity Using A Variable Speed Direct Expansion Air Conditioner
In small to medium scale buildings located in the subtropics, such as Hong Kong, direct expansion air conditioning (DX A/C) systems are widely applied. This is because, as compared to chilled water based central air conditioning systems, DX A/C systems are compact, flexible for multi-room services, energy efficient and cost less to maintain and operate. However, traditionally, a DX A/C system i...
متن کامل