A new rotating-disk sorptive extraction mode, with a copolymer of divinylbenzene and N-vinylpyrrolidone trapped in the cavity of the disk, used for determination of florfenicol residues in porcine plasma.

نویسندگان

  • Alejandro Cañas
  • Samuel Valdebenito
  • Pablo Richter
چکیده

A novel extraction approach was developed based on rotating-disk sorptive extraction (RDSE). In this approach the rotating-disk extraction device consists of a Teflon disk, with a cavity that is loaded with a commercial sorbent phase selected according to the polarity of the analyte. To avoid leakage of the sorbent, the cavity is covered with a fiberglass filter and sealed with a Teflon ring. The proposed novel analytical RDSE technique was used in this study to determine florfenicol levels in plasma as a model analyte, or sample system, to describe the pharmacokinetics of a veterinary formulation. The sorbent used for this application was the copolymer of divinylbenzene and N-vinylpyrrolidone (Oasis HLB), which was selected because the florfenicol molecule contains both hydrophilic and lipophilic moieties. After the extraction, final determination of the analyte was performed by HPLC-DAD. Calibration plots and other analytical features were obtained after 90 min of extraction. The calibration plot was linear over the interval 0.4-16 μg mL(-1) (n = 6), with R (2) = 0.9999. Recovery and repeatability were determined using a blank plasma sample spiked with 4.8 μg mL(-1) florfenicol. A recovery of 91.5 %, with a relative standard deviation (RSD) of 8.8 %, was obtained when the extraction was evaluated using six different rotating-disk devices. Precision was also assessed, using the same disk (containing the same sorbent phase) for eight aliquots of the same sample. The RSD under these conditions was 10.2 %, clearly indicating that the sorptive phase could possibly be re-used. Accordingly, RDSE is a suitable sample preparation alternative to liquid-liquid extraction (LLE), solid-phase extraction (SPE), and stir-bar sorptive extraction (SBSE).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simultaneous Chloramphenicol and Florfenicol Determination by A Validated DLLME-HPLC-UV Method in Pasteurized Milk

The antibiotic residues in milk are a well-known serious problem and pose several health hazards to consumers. We have described a simple, rapid, and inexpensive DLLME-HPLC/UV technique for the extraction of chloramphenicol and florfenicol residues in milk samples. Under the optimum conditions, linearity of the method was observed over the range 0.02-0.85 µg/L with correlation coefficients > 0....

متن کامل

Simultaneous Chloramphenicol and Florfenicol Determination by A Validated DLLME-HPLC-UV Method in Pasteurized Milk

The antibiotic residues in milk are a well-known serious problem and pose several health hazards to consumers. We have described a simple, rapid, and inexpensive DLLME-HPLC/UV technique for the extraction of chloramphenicol and florfenicol residues in milk samples. Under the optimum conditions, linearity of the method was observed over the range 0.02-0.85 µg/L with correlation coefficients > 0....

متن کامل

Nonlinear Finite Element Analysis of Thermoelastic Stresses of FGM Rotating Disk Considering Temperature-Dependency of Material Properties

In the present paper, nonlinear radial and hoop thermoelastic stresses analysis of a disk made of FGMs material is investigated. According to this purpose, finite element method is used. In the present method, second-order one-dimensional element (with three node points) is proposed. The geometrical and stress boundary conditions are defined in the state of non-existence of external pressure an...

متن کامل

Magneto-Thermo-Elastic Stresses and Perturbation of Magnetic Field Vector in a Thin Functionally Graded Rotating Disk

In this paper, a semi-analytical solution for magneto-thermo-elastic problem in an axisymmetric functionally graded (FG) hollow rotating disk with constant thickness placed in uniform magnetic and thermal fields with heat convection from disk’s surfaces is presented. Solution for stresses and perturbation of magnetic field vector in a thin FG rotating disk is determined using infinitesimal theo...

متن کامل

A molecularly imprinted polymer as the sorptive phase immobilized in a rotating disk extraction device for the determination of diclofenac and mefenamic acid in wastewater.

The microextraction of diclofenac and mefenamic acid from water samples was performed by using rotating disk sorptive extraction (RDSE) with molecularly imprinted polymer (MIP) as the sorptive phase. The MIP was synthesized from the monomer 1-vinylimidazol (VI) together with the cross-linker divinylbenzene (DVB) using diphenylamine as the template molecule. Scanning electron microscopy (SEM) an...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical and bioanalytical chemistry

دوره 406 8  شماره 

صفحات  -

تاریخ انتشار 2014