Magnetically-actuated blood filter unit attachable to pre-made biochips.

نویسندگان

  • Kwang Hyo Chung
  • Yo Han Choi
  • Jong-Heon Yang
  • Chan Woo Park
  • Wan-Joong Kim
  • Chil Seong Ah
  • Gun Yong Sung
چکیده

We present a novel blood filter unit that is designed to separate blood plasma from whole blood by simple magnetic actuation. A non-diluted blood sample is dropped into the filter unit and magnetic attraction is applied to squeeze out only blood plasma while blood particles are filtered by membranes stacked in the filter unit. The new filter device yields good filtering performance with nearly perfect filtering efficiency (∼99.999%), high plasma recovery (∼30%), low blood consumption (<50 μl), and fast operation (∼1 min). Because it is simple to operate and is attachable to any kind of pre-made biochip, it has commercial potential in various lab-on-a-chip applications for blood tests.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Leukoreduction in Packed Cell Units Filtered by Home-Made Bedside Filters: Pre and Post Revision of Product Technology and Materials According to Standard Values

Introduction: Leukocytes causing a wide variety of side effects after transfusion are present in all blood products prepared by standard methods. As a consequence, the use of filter technology for leukoreduction has been widely practiced .According to AABB accreditation in 1996, leukoreduced blood components must contain less than 5×106 leukocytes per unit, but sometimes this value is higher ev...

متن کامل

TIME OPTIMAL SLEW MANEUVER OF MAGNETICALLY ACTUATED LEO SATELLITES

Conventional magnetic attitude control methodologies require several orbital periods to accomplish the required attitude maneuvers due to the existence of an uncontrollable axis, namely the local Earth’s magnetic field vector. Since in some attitude maneuver missions the elapsed time is of critical importance, those time-consuming controllers are not satisfactory and we need a much faster contr...

متن کامل

Theoretical and Experimental Study on Magnetically- Actuated Micromirrors for Electromagnetic Nde

Magnetically-actuated Micromirrors as Micro-electromechanical devices have exhibited their superiority over other magnetic sensing techniques in terms of high sensitivity and high spatial resolution, which is favoured not only by quantitative measurement but also imaging of magnetic field distribution. In our research into magnetic field sensing and imaging, a 2D magnetic field sensing system w...

متن کامل

Continuously tunable terahertz metamaterial employing magnetically actuated cantilevers.

Terahertz metamaterial structures that employ flexing microelectromechanical cantilevers for tuning the resonance frequency of an electric split-ring resonator are presented. The tuning cantilevers are coated with a magnetic thin-film and are actuated by an external magnetic field. The use of cantilevers enables continuous tuning of the resonance frequency over a large frequency range. The use ...

متن کامل

Bio-inspired design of submerged hydrogel-actuated polymer microstructures operating in response to pH.

IO N Responsive and reversibly actuating surfaces have attracted signifi cant attention recently due to their promising applications as dynamic materials [ 1 ] that may enable microfl uidic mixing, [ 2 ] particle propulsion and fl uid transport, [ 3 ] capture and release systems, [ 4 ] and antifouling. [ 5 ] Analogs in nature serve as inspiration for the design of such advanced adaptive materia...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Lab on a chip

دوره 12 18  شماره 

صفحات  -