Imaging the carotid bifurcation using continuous-wave Doppler-shift ultrasound and spectral analysis.
نویسندگان
چکیده
A non-invasive method is described for visualizing the carotid bifurcation using a continuous-wave Doppler-shift technique simultaneously with spectral analysis of the blood velocities from all parts of the vessel lumen. The system is directional so that arteries can be visualized in the presence of signals from adjacent veins. The technique uses a transducer which is attached to a position-sensing arm so that the position of the ultrasound beam on the neck, when sensing arterial blood flow-velocities, can be translated onto a storage oscilloscope. By repeated passes of the transducer across the vessel lumen a 2 dimensional image of the carotid bifurcation is formed. As each image point is marked, the full spectrum of blood-velocities corresponding to that position is continuously displayed on a second oscilloscope beside the image scope. Ultrasound images are compared with arteriograms and both continuous-wave and pulsed Doppler ultrasound imaging systems are discussed.
منابع مشابه
Comparison of Doppler ultrasonography with arteriography of the carotid artery bifurcation.
Continuous-wave (CW) Doppler ultrasound imaging for prediction of arteriogrphic abnormality at the carotid bifurcation was carried out in 195 arteries of 105 patients. The Doppler method had no predictive value when compared to angiographic findings in arteries classified as 0-50% stenosis by Doppler. In 50-75% stenosis by arteriography Doppler accuracy was 52%. With stenosis of 76-99% Doppler ...
متن کاملComparison of ultrasound and IV-DSA for carotid evaluation.
Sixty carotid bifurcations in 34 symptomatic patients were examined prospectively with ultrasound (continuous wave Doppler and high resolution, B-mode imaging) and intravenous digital subtraction angiography (IV-DSA). The overall quality of examination was better with DSA than with ultrasound. Imaging of the external carotid artery was particularly difficult with sonography. For evaluation of t...
متن کاملCorrelation of continuous-wave Doppler spectral flow analysis with gross pathology in carotid stenosis.
Preoperative continuous-wave Doppler spectral analysis was used to generate two parameters, peak frequency in the internal carotid artery (fmax) and the ratio of peak frequencies in the internal and common carotid arteries (carotid index). These were compared with direct measurement of residual lumen diameter in pathologic specimens obtained from carotid endarterectomy in 37 patients. Doppler s...
متن کاملDiagnosis by ultrasound of severe carotid artery disease in patients undergoing cardiopulmonary bypass operations.
A non-invasive method using continuous wave Doppler shift ultrasound and spectral analysis was used as a screening test for severe carotid artery disease in patients undergoing cardiopulmonary bypass operations. One hundred and eighty-eight patients were examined before cardiac surgery (91 for ischaemic heart disease, 17 for ischaemic heart disease and valve replacement, 66 for valve replacemen...
متن کاملProblems of carotid Doppler scanning which can be overcome by using frequency analysis.
The value of the concomittant use of a real time frequency analyzer along with a continuous wave carotid Doppler scanner is demonstrated in this study of 118 cases. With a colour-coded Doppler scanner alone, internal carotid stenoses greater than 35% were diagnosed with a sensitivity of 95% and a specificity of 82%. With the addition of frequency analysis certain inherent problems with Doppler ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Stroke
دوره 9 5 شماره
صفحات -
تاریخ انتشار 1978