Characterization of indoor bioaerosols from a hospital ward in a tropical setting.

نویسندگان

  • S Sudharsanam
  • S Swaminathan
  • A Ramalingam
  • G Thangavel
  • R Annamalai
  • R Steinberg
  • K Balakrishnan
  • P Srikanth
چکیده

OBJECTIVES Study was conducted to assess whether temporal variation exists in airborne microbial concentrations of a hospital ward (west-Chennai, India) using active and passive methods, and characterise the microorganisms. METHODS Air samples (duplicates) were collected simultaneously using exposed-plate, impingement (BioSampler) and filtration (personal sampling filter cassette loaded with gelatin filter) methods over different periods of the year. Bacterial plates were incubated at 37°C and observed for growth after 48h; fungal plates were incubated at 25°C and 37°C and observed upto 7 days. Microorganisms were identified using standard microbiological procedures. RESULTS Microbial loads were found to vary with the sampling method. Concentrations of bacteria were higher (exposed-plate: 45-150 CFU/plate; impingement: 1.12E+03-1.6856E+05 CFU/m(3); filtration: 3.788E+03-1.91111E+05 CFU/m(3)) than fungi (exposed-plate: 0-13 CFU/plate; impingement: 0-3.547E+03 CFU/m(3); filtration: 0-1.515E+04 CFU/ m(3)). Coagulase-negative Staphylococci and Micrococci were the predominant Gram-positive cocci in active and passive samples. Enterobacter and Pseudomonas were the predominant Gram-negative bacilli. Among fungi, Aspergillus niger was isolated throughout the year. There was no significant temporal variation in airborne microbial loads irrespective of methods. CONCLUSIONS Exposed-plate method was found to capture microorganisms efficiently with little variation in duplicate samples, suggesting its use in hospitals for preliminary assessment of indoor air quality and determine pathogenic microorganisms due to particle fall-out.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

this study, density and type of bioaerosols in the indoor-air are studied in Imam Sajjad Hospital, Yasuj.

Abstract: The effect of polluted air on human health and survival is undeniable. Bioaerosols in the breathing air, can affect human health in different ways. Bioaerosol are particles transported by air and include bacteria, fungi, viruses and other substances. Bioaerosols may cause nosocomial infections that affect all hygienic, economic and social aspects of the individuals. Given that hospit...

متن کامل

بررسی بیوآئروسل های قارچی و ذرات معلق هوای داخل و آزاد بیمارستان های آموزشی- درمانی شهر خرم آباد در زمستان 93 و بهار 94

Background and Objective: The presence of fungal bioaerosols in hospitals indoor environments have affected the health of patients with the defect in immunity system. Therefore, determination of the rate and species of these agents is essential. This study aimed to investigate association between fungi contamination and particulate matter (PM10, PM2.5 and PM1) concentrations in the main indoor ...

متن کامل

Indoor and Outdoor Air Fungus Bioaerosols in Khorramabad Day Care Child Centers Western of Iran, 2018

Introduction: the aim of this study was to determine the quantity and quality of indoor and outdoor air fungus bioaerosols in Khorramabad day care child centers. Materials and Methods: A total of 180 air samples were collected from 10 centers in 2018. The samples included 7 indoor and 2 outdoor sampling points. The total number of children was 580. Sampling of fungal bioaerosols was performed ...

متن کامل

بررسی بیوآئروسل های قارچی محیط داخل و فضای آزاد و ارتباط آن با ذرات معلق در یک بیمارستان در شهر خرم آباد

Background: The climate change and particulate matter emission contented of bioaerosols is known as an important reason of increasing the allergic interactions especially in patients with defect in immunity system. The aim of this study was to investigate fungal bioaerosol concentrations in relation to particulate matter (PM10, PM2.5 and PM1) in indoor parts and ambient air of the generd educat...

متن کامل

High bacterial load of indoor air in hospital wards: the case of University of Gondar teaching hospital, Northwest Ethiopia

BACKGROUND The air inhaled by people is abundantly populated with microorganisms which also are called bioaerosols. Bioaerosols is a colloidal suspension, formed by liquid droplets and particles of solid matter in the air, whose components contain or have attached to them viruses, fungal spores and conidia, bacterial endospores, plant pollen and fragments of plant tissues. They account for 5-34...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • African health sciences

دوره 12 2  شماره 

صفحات  -

تاریخ انتشار 2012