On the need for monitor unit calculations as part of a beam commissioning methodology for a radiation treatment planning system
نویسندگان
چکیده
This paper illustrates the need for validating the calculation of monitor units as part of the process of commissioning a photon beam model in a radiation treatment planning system. Examples are provided in which this validation identified subtle errors, either in the dose model or in the implementation of the dose algorithm. These errors would not have been detected if the commissioning process only compared relative dose distributions. A set of beam configurations, with varying field sizes, source-to-skin distances, wedges, and blocking, were established to validate monitor unit calculations for two different beam models in two different radiation treatment planning systems. Monitor units calculated using the treatment planning systems were compared with monitor units calculated from point dose calculations from tissue-maximum ratio (TMR) tables. When discrepancies occurred, the dose models and the code were analyzed to identify the causes of the discrepancies. Discrepancies in monitor unit calculations were both significant (up to 5%) and systematic. Analysis of the dose computation software found: (1) a coordinate system transformation error, (2) mishandling of dose-spread arrays, (3) differences between dose calculations in the commissioning software and the planning software, and (4) shortcomings in modeling of head scatter. Corrections were made in the beam calculation software or in the data sets to overcome these discrepancies. Consequently, we recommend incorporating validation of monitor unit calculations as part of a photon beam commissioning process.
منابع مشابه
Evaluation of treatment planning system monitor unit calculations for three intensity modulated radiotherapy delivery techniques
Background: We have validated the monitor unit calculations from a commercially available treatment planning system (TPS) for three intensity modulated radiotherapy (IMRT) planning techniques for tangential breast irradiation by using ionization chamber measurements. Materials and Methods: Treatment plans were generated for forty-two breast patients by a forward planned field in field ...
متن کاملVerification of Monitor unit calculations for eclipse Treatment Planning System by in- house developed spreadsheet
Introduction: Computerized treatment planning is a rapidly evolving modality that depends on hardware and software efficiency. Despite ICRU recommendations suggesting 5% deviation in dose delivery the overall uncertainty shall be less than 3.5% as suggested by B.J. Minjnheer. J. In house spreadsheets are developed by the medical physicists to cross-verify the dose calculated by the Treatment Pl...
متن کاملEvaluation of a systemic change of Superficial X-ray tube characteristics
Introduction: Very low, Low and Medium X-ray machines are used extensively for Superficial Radiation Therapy mostly used for Basal Cell, Squamous Cell Carcinoma, and Melanoma skin cancers. In most of cases, Superficial X-ray Therapy (SXRT) is preferred to Electron beams generated using a linear accelerator. SXRT tube characteristics may vary with the use of the machine for a lo...
متن کاملThe comparison between 6 MV Primus LINAC simulation output using EGSnrc and commissioning data
Introduction: Monte Carlo calculation method is considered to be the most accurate method for dose calculation in radiotherapy. The purpose of this research is comparison between 6 MV Primus LINAC simulation output with commissioning data using EGSnrc and build a Monte Carlo geometry of 6 MV Primus LINAC as realistically as possible. The BEAMnrc and DOSXYZnrc (EGSnrc package) M...
متن کاملCommissioning and early experience with a new generation low-energy linear accelerator in zahedan
Introduction: Since commissioning beam data are treated as a reference and ultimately used by treatment planning systems, it is vitally important that the collected data are of the highest quality to avoid dosimetric and patient treatment errors that may subsequently lead to a poor radiation outcome. Beam data commissioning should be performed with appropriate knowledge and pr...
متن کامل