Modifying the Three-phase Synchronous Reference Frame Phase-locked Loop to Remove Unbalance and Harmonic Errors
نویسندگان
چکیده
...........................................................................................................................................ii Acknowledgements.........................................................................................................................iii Table of
منابع مشابه
Enhanced Frequency-Adaptive Phase-Locked Loop for Distributed Power Generation System Applications
The standards governing the grid connection of distributed power generation systems (DPGS) are becoming increasingly demanding due to the growing number of alternative energies being connected to the grid. Grid connection standards now place greater emphasis on the fault ride-through capabilities of the DPGS. In order to fulfill these standards, improvements must be made to the grid-side contro...
متن کاملA New PLL Simulation Validation for Three-phase Grid under Heavy Distorted Conditions
The precision of phase-locked loop (PLL) has a direct effect on the output performance for three-phase grid-connected inverter or three-phase active PFC. In this paper, a new three-phase digital closed-loop phase-locked algorithm is proposed on the basis of synchronous reference frame transformation. Synchronous simulation of the PLL techniques is a good choice even if the polluted three-phase ...
متن کاملThree-phase Magnitude-phase Detection Based on T/4 Time-lapse Elimination Method
Affected by the negative sequence component and harmonic component of three-phase grid, the conventional three-phase software phase-locked loop (SPLL) circuits were unable to extract the magnitude-phase information of three-phase fundamental positive sequence component accurately, and the dynamic response speed was slow. In order to solve this problem, this paper introduces T/4 time-lapse elimi...
متن کاملActive Filter Control Method Based on Direct Power Control for Compensating Reactive Powers due to Unbalanced Voltages and Nonlinear Loads
Active filters have proven to be more effective than passive techniques to improve power quality and to solve harmonic and power factor problems due to nonlinear loads. This paper proposes a control scheme based on the instantaneous active and reactive power. The inverter of this active filter is a three-phase, two-level converter. Space vector technique is used as modulators and pattern genera...
متن کاملComparative Power Quality Analysis of Different DSTATCOM Topologies
This paper presents the three topologies of three-phase four-wire DSTATCOM for reduction of harmonics, reactive power compensation, increasing power factor, which occur due to a nonlinear load, environment problem and polluted grid. The performances of the above topologies have been compared for the magnitude of source current, power factor improvement, DC-link voltage regulation, and total har...
متن کامل