PCA-based denoising method for division of focal plane polarimeters.
نویسندگان
چکیده
Division of focal plane (DoFP) polarimeters are composed of interlaced linear polarizers overlaid upon a focal plane array sensor. The interpolation is essential to reconstruct polarization information. However, current interpolation methods are based on the unrealistic assumption of noise-free images. Thus, it is advantageous to carry out denoising before interpolation. In this paper, we propose a principle component analysis (PCA) based denoising method, which works directly on DoFP images. Both simulated and real DoFP images are used to evaluate the denoising performance. Experimental results show that the proposed method can effectively suppress noise while preserving edges.
منابع مشابه
Image interpolation and denoising for division of focal plane sensors using Gaussian processes.
Image interpolation and denoising are important techniques in image processing. These methods are inherent to digital image acquisition as most digital cameras are composed of a 2D grid of heterogeneous imaging sensors. Current polarization imaging employ four different pixelated polarization filters, commonly referred to as division of focal plane polarization sensors. The sensors capture only...
متن کاملOptimised polarimeter configurations for measuring the Stokes parameters of the Cosmic Microwave Background Radiation
We present configurations of polarimeters which measure the three Stokes parameters I, Q and U of the Cosmic Microwave Background Radiation with a nearly diagonal error matrix, independent of the global orientation of the polarimeters in the focal plane. These configurations also provide the smallest possible error box volume.
متن کاملFOCAL POINT AND FOCAL K-PLANE
This paper deals with the basic notions of k-tautimmersions . These notions come from two special cases; that is, tight and taut immersions. Tight and taut based on high and distance functions respectively and their basic notions are normal bundle, endpoint map, focal point, critical normal. We generalize hight and distance functions to cylindrical function and define basic notions of k-taut ...
متن کاملOptimised Polarimeter Conngurations for Measuring the Stokes Parameters of the Cosmic Microwave Background Radiation
the date of receipt and acceptance should be inserted later Abstract. We present conngurations of polarimeters which measure the three linear Stokes parameters of the Cosmic Microwave Background Radiation with a nearly diagonal error matrix, independent of the global orientation of the polarimeters in the focal plane. These conngurations also provide the smallest possible error box volume.
متن کاملAntenna-coupled TES Arrays For The BICEP2/Keck and SPIDER polarimeters
The upcoming Cosmic Microwave Background (CMB) experiments BICEP2/Keck and SPIDER will be using planar arrays of polarization sensitive antenna-coupled TES bolometers, operating at frequencies between 96GEIZ and 220 GEIz. At 145 GlTz each array consists of 64 polarimeters (128 TES sensors) and four of these arrays are assembled together to make a focal plane. The detector arrays are integrated ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Optics express
دوره 25 3 شماره
صفحات -
تاریخ انتشار 2017