Pen needle design influences ease of insertion, pain, and skin trauma in subjects with type 2 diabetes

نویسندگان

  • Kezia A Præstmark
  • Morten L Jensen
  • Nils B Madsen
  • Jonas Kildegaard
  • Bente M Stallknecht
چکیده

OBJECTIVE Pen needles used for subcutaneous injections have gradually become shorter, thinner and more thin walled, and thereby less robust to patient reuse. Thus, different needle sizes, alternative tip designs and needles resembling reuse were tested to explore how needle design influences ease of insertion, pain and skin trauma. RESEARCH DESIGN AND METHODS 30 subjects with injection-treated type 2 diabetes and body mass index 25-35 kg/m2 were included in the single-blinded study. Each subject received abdominal insertions with 18 different types of needles. All needles were tested twice per subject and in random order. Penetration force (PF) through the skin, pain perception on 100 mm visual analog scale, and change in skin blood perfusion (SBP) were quantified after the insertions. RESULTS Needle diameter was positively related to PF and SBP (p<0.05) and with a positive pain trend relation. Lack of needle lubrication and small 'needle hooks' increased PF and SBP (p<0.05) but did not affect pain. Short-tip, obtuse needle grinds affected PF and SBP, but pain was only significantly affected in extreme cases. PF in skin and in polyurethane rubber were linearly related, and pain outcome was dependent of SBP increase. CONCLUSIONS The shape and design of a needle and the needle tip affect ease of insertion, pain and skin trauma. Relations are seen across different data acquisition methods and across species, enabling needle performance testing outside of clinical trials. TRIAL REGISTRATION NUMBER NCT02531776; results.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Impact of a modified needle tip geometry on penetration force as well as acceptability, preference, and perceived pain in subjects with diabetes.

BACKGROUND Multiple factors impact subcutaneous insulin injection pain. Injection devices [e.g., syringe or pen needle (PN)] affect pain due to needle length, diameter, needle polishing and lubrication, and needle tip geometry. METHODS We evaluated a modified 5-bevel PN tip in 32 G × 4 mm 31 G × 5 mm and 8 mm PNs vs the equivalent marketed 3-bevel PNs in laboratory penetration force testing, ...

متن کامل

Glycemic control, reported pain and leakage with a 4 mm × 32 G pen needle in obese and non-obese adults with diabetes: a post hoc analysis.

OBJECTIVE The shortest pen needle (PN) for subcutaneous insulin therapy is 4 mm. Clinicians may hesitate to use it in obese patients. We report a post hoc analysis of a previously published study of the 4 mm × 32 G PN, evaluating responses in obese (≥30 kg/m(2)) and non-obese (<30 kg/m(2)). METHODS Subjects (BMI 20 to 49 kg/m(2), 52% obese) with diabetes used 4 mm × 32 G PNs and either 5 mm o...

متن کامل

Skin and subcutaneous thickness at injecting sites in children with diabetes: ultrasound findings and recommendations for giving injection.

BACKGROUND Children who inject insulin need clear guidelines as to the length of needle best for them. We studied the distance from surface to muscle in children in order to make needle choices which are evidence-based. METHODS One hundred one children with type 1 diabetes were divided into three groups according to age: 2-6, 7-13, and 14-17 yr. The thickness of skin and subcutaneous (SC) tis...

متن کامل

Intravenous Skin Changes Following Treatment of Tibial Fracture and Associated Factors

 Background and purpose: Skin complications may occur in distal tibial fractures in poor skin and soft tissue conditions and poor blood flow. The aim of this study was to evaluate venous skin changes one to six years after tibial fractures. Materials and methods: This cross-sectional study was performed in 140 patients with tibial fracture who were treated with one of the intramedullary method...

متن کامل

What can we learn from patient-reported outcomes of insulin pen devices?

Although a variety of effective treatment options are available for patients with type 1 or type 2 diabetes, many patients in the United States have difficulty reaching their glycemic goals. Patient adherence to insulin therapy, which often involves self-administered subcutaneous injections of insulin using either a vial and syringe or an insulin pen device, is often poor. Various factors assoc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 4  شماره 

صفحات  -

تاریخ انتشار 2016