An empirical method for lag correction in cone-beam CT.

نویسندگان

  • N Mail
  • D J Moseley
  • J H Siewerdsen
  • D A Jaffray
چکیده

Image lag degrades image quality in cone-beam CT (CBCT), resulting in contrast reduction, lack of CT number accuracy and uniformity, and skin-line artifacts. The magnitude of such degradation and the extent to which imaging performance can be improved by means of a lag correction method were investigated. Measurements were performed using a radiotherapy CBCT guidance system (Elekta Synergy XVI, Elekta Oncology Systems, Atlanta, GA), for which the imaging system is based upon a RID1640-AL1 flat-panel imager (Perkin Elmer, Wiesbaden, Germany). Image lag and its relationship to various parameters including signal magnitude, photon energy, and frame number were investigated, and an empirical lag correction method was developed to manage lag artifacts. The correction method was simply the subtraction from the current frame by previous frames weighted by the temporal response function. The CatPhan 500 phantom (The Phantom Laboratory, Salem, NY) within an irregularly shaped body annulus was used to demonstrate the magnitude of artifacts with and without lag correction. CBCT images after correction demonstrated improvement in skin-line reconstruction, CT number accuracy, image uniformity, and contrast-to-noise ratio. Lag artifacts can be reduced by means of algorithmic correction of the projection images. Lag correction is most important for all shapes of objects having contrast inserts. For circular/cylindrical objects, lag correction does not improve the skin-line artifact but can improve low contrast visibility adjacent to high contrast objects.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Artifact reduction techniques in Cone Beam Computed Tomography (CBCT) imaging modality

Introduction: Cone beam computed tomography (CBCT) was introduced and became more common based on its low cost, fast image procedure rate and low radiation dose compared to CT. This imaging modality improved diagnostic and treatment-planning procedures by providing three-dimensional information with greatly reduced level of radiation dose compared to 2D dental imaging modalitie...

متن کامل

Validation of computed tomography-based attenuation correction of deviation between theoretical and actual values for four computed tomography scanners

Objective: In this study, we aimed to validate the accuracy of computed tomography-based attenuation correction (CTAC) using the bilinear scaling method.Methods: The measured attenuation coefficient (μm) was compared to a theoretical attenuation coefficient (μt ) using four different CT scanners and an RMI 467 phantom. The effective energy of the CT beam X-rays was calculated, using the aluminu...

متن کامل

Usability assessment of cone beam computed tomography with a full-fan mode bowtie filter compared to that with a half-fan mode bowtie filter

Background: In intensity modulated radiation therapy, cone beam computed tomography (CT) has been used to evaluate patients prior to treatment. This study conducted a comparative evaluation of the image reconstruction ability of the clinically used half-fan bowtie filter and the full-fan bowtie filter. Materals and Methods: A CT simulation marker was inserted inside a human phantom, and the pel...

متن کامل

Empirical cupping correction: a first-order raw data precorrection for cone-beam computed tomography.

We propose an empirical cupping correction (ECC) algorithm to correct for CT cupping artifacts that are induced by nonlinearities in the projection data. The method is raw data based, empirical, and requires neither knowledge of the x-ray spectrum nor of the attenuation coefficients. It aims at linearizing the attenuation data using a precorrection function of polynomial form. The coefficients ...

متن کامل

Beam Attenuation Grid–Based Scatter Correction Algorithm for Cone Beam Volume CT

In the flat panel detector-based cone beam CT system, the scatter photons which reach the flat panel detector increase the detected signal, produce the image cupping artifact and reduce the image contrast. To conquer the X-Ray scatter problem, this study proposes the beam attenuation grid -based scatter correction algorithm that needs to add a beam attenuation grid (BAG) between the X-Ray sourc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical physics

دوره 35 11  شماره 

صفحات  -

تاریخ انتشار 2008