Comparison of tools and techniques for implanting pacemaker leads on the ventricular mid-septum.

نویسندگان

  • Haran Burri
  • Giulia Domenichini
  • Henri Sunthorn
  • Vincent Ganière
  • Carine Stettler
چکیده

INTRODUCTION Many physicians target the interventricular septum for pacemaker implantation, but the lead may inadvertently end up in an anterior position. AIMS We sought to compare two stylet shapes to achieve mid-septal lead placement, as well as the utility of a novel right anterior oblique (RAO) fluoroscopic landmark. METHODS AND RESULTS Patients undergoing pacemaker implantation were enrolled into four consecutive groups according to stylet shape: a standard curve [two-dimensional (2D) stylet] or with an additional distal posterior curve [three-dimensional (3D) stylet], and whether RAO fluoroscopy was used. Left oblique anterior (LAO) and postero-anterior (PA) fluoroscopic views were used in all cases. After implantation, validation of right ventricular lead position (septal vs. anterior) was performed by echocardiography. A total of 113 patients were included, of whom lead position could be validated in 106 patients. Septal position was achieved in only 10 of 22 (45%) patients in the 2D stylet group and in 17 of 23 (74%) patients in the 3D stylet group (P = 0.07) when only PA and LAO fluoroscopy were used. Results were significantly improved by additional use of RAO fluoroscopy, with successful septal placement in 25 of 28 (89%) patients in the 2D stylet + RAO group (P = 0.001) and 32 of 33 (97%) patients in the 3D stylet + RAO group (P = 0.015). CONCLUSIONS A septal lead position was obtained in only about half of the patients when a 2D stylet was used with only LAO and PA fluoroscopic views. A 3D stylet was useful to attain the target position, and additional RAO fluoroscopy significantly improved success rate with both stylet shapes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

How can we identify the optimal pacing site in the right ventricular septum? A simplified method applicable during the standard implanting procedure.

AIMS A short paced (p) QRS duration (d) can be a marker for selecting the most appropriate RV pacing site. Although this could be achieved by continual 12-Lead ECG monitoring, such a technique is not applicable during pacemaker (PM) implantation. The purpose of this study was to validate a method for identifying the optimal site for RV septum pacing using simple markers derived from few real-ti...

متن کامل

Comparison of Fetal Echocardiography for Fetal Cardiac Structure in Women with Gestational Diabetes Mellitus and Normal Pregnancies

BackgroundIncreased metabolic rate of hyperglycemia in gestational diabetes causes macrosomia, which can also affect the fetal heart. The thickness of the walls of the heart and its function in women with gestational diabetes mellitus (GDM) can change over time before treatment. We aimed to evaluate fetal cardiac structure in terms of ventricular wall thickness and its function in women w...

متن کامل

Safety, Handling and Electrical Performances of Bradycardia Leads in Acute Conditions: Results from the FINE Registry

Background: Beflex is an active fixation atrial and ventricular lead with a retractable screw; X-Fine is a passive fixation ventricular lead. These two bradycardia lead models were evaluated in the FINE study, an observational prospective trial conducted in France and Spain. Methods: Patients enlisted for pacemaker or defibrillator implants were enrolled. The primary objective was to assess acu...

متن کامل

Pacemaker Twiddler's Syndrome

A 76-yr-old man with unipolar ventricular pacemaker, previously implanted in the right ventricular apex, presented with syncopal attack and twitching of the right pectoralis muscle. He finally was diagnosed as having Twiddler's syndrome. The patient had a pulse rate of 36/min and cannon waves in the neck veins. Chest radiography showed a dislodged pacing lead completely wrapped around the pulse...

متن کامل

Surgical Repair of Subacute Right Ventricular Perforation after Pacemaker Implantation

We report an 84-year-old woman who presented with right ventricular perforation 4 days after pacemaker implantation for syncope due to sick sinus syndrome. Median sternotomy revealed no pericardial effusion, but the pacing lead had penetrated the right ventricle and pericardium. When the pleura was opened, the tip of the lead was seen in the visceral pleura. The lead was cut in the pericardial ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology

دوره 14 6  شماره 

صفحات  -

تاریخ انتشار 2012