Modeling & Simulation of DSTATCOM for Power Quality Improvement

نویسندگان

  • N.Srinivasa Rao
  • Krishna Rao
چکیده

–A Power quality problem is an occurrence manifested as a nonstandard voltage, current or frequency that results in a failure or a mis-operation of end user equipments. Utility distribution networks, sensitive industrial loads and critical commercial operations suffer from various types of outages and service interruptions which can cost significant financial losses. With the restructuring of power systems and with shifting trend towards distributed and dispersed generation, the issue of power quality is going to take newer dimensions. In developing countries like India, where the variation of power frequency and many such other determinants of power quality are themselves a serious question, it is very vital to take positive steps in this direction .This paper presents a study on the modeling of a STATCOM (Static Synchronous Compensator) used for reactive power compensation on a distribution network. This paper deals with the simulation of distribution static synchronous compensator (DSTATCOM) for improving power quality of a distribution system feeding linear as well as non-linear loads. Nowadays, there are an increasing number of non-linear loads which inject harmonics into the system. A three-phase insulated gate bipolar transistor(IGBT-) based current controlled voltage source inverter with a DC bus capacitor known as a DSTATCOM is used for power factor correction, harmonic compensation and for providing required reactive power to the load. A model of DSTATCOM connected to a power distribution system feeding linear and non-linear loads (diode bridge rectifier with R and R-C) is developed for predicting the behavior of system under transient conditions. Simulation is carried out in standard MATLAB environment using Simulink and power system blockset toolboxes. Finally the performance of DSTATCOM under various fault conditions is investigated. Keywords––D-STATCOM, Voltage Sags, Voltage Source Converter (VSC).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparative Power Quality Analysis of Different DSTATCOM Topologies

This paper presents the three topologies of three-phase four-wire DSTATCOM for reduction of harmonics, reactive power compensation, increasing power factor, which occur due to a nonlinear load, environment problem and polluted grid. The performances of the above topologies have been compared for the magnitude of source current, power factor improvement, DC-link voltage regulation, and total har...

متن کامل

Dstatcom Based Five-level Cascade H-bridge Multilevel Inverter for Power Quality Improvement

Power electronic device, nonlinear and unbalanced loads have given rise to power quality problem in distribution systems. Due to factors like competitive generation patterns in a deregulated electric grid and an increasing level of sensitive end user devices, it has become necessary to ensure both reliable and power quality to the end customer. One way to betterment the power quality is using a...

متن کامل

Study And Characterisation Of Electrolytic Capacitor-Bank And Ultra Capacitor Energy Source In DSTATCOM

This paper discusses the dynamic performance and the modeling of a DSTATCOM with Capacitor Bank (CB) and Ultra Capacitor Energy Storage (UCES) considering their equivalent series resistance for improving the operation of power quality in power distribution system. The proposed integrated DSTATCOM system is studied for riding through voltage sags and dynamically controlling active power independ...

متن کامل

Artificial Neural Network Controlled DSTATCOM for Power Quality Improvement

Abstract: The paper intends to develop the artificial neural network control algorithm for the control of DSTATCOM for the improvement of power quality. The presence of nonlinear loads makes the voltage to be deviated and current to be distorted from its sinusoidal waveform quality. Thus harmonics elimination, load balancing and voltage regulation is the heavy task that has to be accomplished t...

متن کامل

Fuzzy Controlled DSTATCOM for Voltage Sag Compensation and DC-Link Voltage Improvement

In this paper we propose fuzzy control of DC-link capacitor voltage of three-phase four-wire DSTATCOM for power quality improvement in distribution network. It is designed to compensate reactive power and to eliminate harmonic currents. DSTATCOM regulates the voltage at the point of common coupling (PCC) by injecting reactive power to the PCC. During load changes there is considerable variation...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012