Pseudoaneurysm after arthroscopic subacromial decompression and distal clavicle excision.
نویسندگان
چکیده
Arthroscopic shoulder surgery is considered a safe and effective method of treating a variety of shoulder pathologies and is associated with a low complication rate. The type and rate of complications can vary, depending on the procedure, positioning, surgical time, and anesthesia. Fortunately, neurovascular injuries occur infrequently. Numerous studies have described the proximity of neurovascular structures to portals placed in shoulder arthroscopy, in both the beach chair and the lateral decubitus positions. Accurate portal placement is important to avoid damage to adjacent neurovascular structures. Inaccurate placement of portals can lead to inadvertent damage to these structures and create more difficulty with visualization and angle of instrumentation, possibly compromising the success of the procedure. This article describes a 50-year-old man who underwent arthroscopic subacromial decompression and distal clavicle excision for persistent subacromial impingement and acromioclavicular arthritis. During postoperative follow-up, the patient had a small, bulging area located near the anterior portal site. Examination showed a well-healed anterior portal site with a small (approximately 2×2 cm), nontender, immobile mass located within the deep soft tissues just below the anterior portal incision. Ultrasound evaluation showed a pseudoaneurysm of a branch off the axillary artery. The patient underwent successful embolization of the pseudoaneurysm, with complete resolution of symptoms.
منابع مشابه
Arthroscopic Resection of The Distal Clavicle With Concomitant Subacromial Decompression: A Case Series
ABSTRACT Shoulder impingement syndrome and acromioclavicular joint osteoarthritis often occur simultaneously and easily missed. Kay et al. reported excellent results with combined arthroscopic subacromial decompression and resection of the distal end of the clavicle in patients with both disorders(1). Arthroscopic treatment of these disorders produces more favourable results than open procedure...
متن کاملArthroscopic Management of Shoulder Osteoarthritis
Osteoarthritis (OA) can cause severe pain and dysfunction of the shoulder. When conservative treatment fails and operative treatments such as shoulder arthroplasty and open glenohumeral resurfacing are not advisable, shoulder arthroscopy may be used to treat shoulder OA. Arthroscopic treatment of concomitant pathology in the shoulder including subacromial decompression, labral repair, capsular ...
متن کاملArthroscopic decompression of the suprascapular nerve at the spinoglenoid notch and suprascapular notch through the subacromial space.
Suprascapular nerve entrapment can cause disabling shoulder pain. Suprascapular nerve release is often performed for compression neuropathy and to release pressure on the nerve associated with arthroscopic labral repair. This report describes a novel all-arthroscopic technique for decompression of the suprascapular nerve at the suprascapular notch or spinoglenoid notch through a subacromial app...
متن کاملEffects of conservative therapy applied before arthroscopic subacromial decompression on the clinical outcome in patients with stage 2 shoulder impingement syndrome.
BACKGROUND/AIM To investigate the effects of conservative therapy applied before arthroscopic subacromial decompression on the clinical outcome in patients with stage 2 shoulder impingement syndrome. MATERIALS AND METHODS Sixty-eight patients having stage 2 shoulder impingement syndrome and treated with arthroscopic subacromial decompression were included in the study. We divided these patien...
متن کاملThe role of acromion morphology in chronic subacromial impingement syndrome.
This study investigated the role of acromion morphology in the aetiology of chronic subacromial impingement syndrome. Forty five patients with chronic subacromial impingement syndrome were included in the study. They were distributed into three groups according to their acromion types: six (13.3%) patients had type 1, 24 (533%) patients type 2 and 15 (333%) patients type 3 acromion. Constant sc...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Orthopedics
دوره 37 6 شماره
صفحات -
تاریخ انتشار 2014