Hearing preservation surgery: psychophysical estimates of cochlear damage in recipients of a short electrode array.

نویسندگان

  • René H Gifford
  • Michael F Dorman
  • Anthony J Spahr
  • Sid P Bacon
  • Henryk Skarzynski
  • Artur Lorens
چکیده

In the newest implementation of cochlear implant surgery, electrode arrays of 10 or 20 mm are inserted into the cochlea with the aim of preserving hearing in the region apical to the tip of the electrode array. In the current study two measures were used to assess hearing preservation: changes in audiometric threshold and changes in psychophysical estimates of nonlinear cochlear processing. Nonlinear cochlear processing was evaluated at signal frequencies of 250 and 500 Hz using Schroeder phase maskers with various indices of masker phase curvature. A total of 15 normal-hearing listeners and 13 cochlear implant patients (7 with a 10 mm insertion and 6 with a 20 mm insertion) were tested. Following surgery the mean low-frequency threshold elevation was 12.7 dB (125-750 Hz). Nine patients had postimplant thresholds within 5-10 dB of preimplant thresholds. Only one patient, however, demonstrated a completely normal nonlinear cochlear function following surgery--although most retained some degree of residual nonlinear processing. This result indicates (i) that Schroeder phase masking functions are a more sensitive index of surgical trauma than audiometric threshold and (ii) that preservation of a normal cochlear function in the apex of the cochlea is relatively uncommon but possible.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Investigating the Effect of Cochlear Size in Insertion of Electrode Depth in Patients with Cochlear Implantation evaluated by CT-Scan

Background Cochlear implant surgery is an invasive procedure for patients with bilateral Sensorineural hearing loss and may cause some risks such as cochlear damage. We aimed to evaluate the effectiveness of cochlear measures obtained by computed tomography (CT) scan in predicting depth of cochlear implant insertion. Materials and Methods This study was conducted in a retrospective and cross-se...

متن کامل

Evaluation of Intracochlear Trauma Caused by Insertion of Cochlear Implant Electrode Arrays through Different Quadrants of the Round Window

HYPOTHESIS This study aimed to evaluate whether there is a difference in the degree of intracochlear trauma when the cochlear implant electrode arrays is inserted through different quadrants of the round window membrane. BACKGROUND The benefits of residual hearing preservation in cochlear implant recipients have promoted the development of atraumatic surgeries. Minimal trauma during electrode...

متن کامل

[Hearing preservation results after cochlear implantation in short-term and long-term observation].

OBJECTIVE To estimate a residual hearing preservation in cochlear implant patients in short-, and long-term observation. MATERIAL AND METHODS A group of 40 subjects with preserved residual hearing were included to this study. In all of them cochlear implant was provided due to a neurosensonal hearing loss. In all subjects hearing was tested using traditional audiological test battery. Cochlea...

متن کامل

Methods of Hearing Preservation during Cochlear Implantation

Introduction  Recent advances in surgical techniques and electrode design have made residual hearing preservation during cochlear implantation (CI) possible, achievable, and desirable. Objectives  The objective of this study was to review the literature regarding methods used for hearing preservation during CI surgery. Data Synthesis  We performed a search in the LILACS, MEDLINE, SciELO, PubMed...

متن کامل

The use of micro-CT to evaluate cochlear implant electrode position and intracochlear damage.

1. Balkany TJ, Connell SS, Hodges AVet al. Conservation of residual acoustic hearing after cochlear implantation. Otol Neurotol 2006;27:1083-8. 2. von Ilberg C, Kiefer J, Tillein Jet al. Electric-acoustic stimulation of the auditory system. New technology for severe hearing loss. ORL; journal for oto-rhino-laryngology and its related specialties 1999;61:334-40. 3. Gantz BJ, Turner CW. Combining...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The Journal of the Acoustical Society of America

دوره 124 4  شماره 

صفحات  -

تاریخ انتشار 2008