Sonographic prediction of scar dehiscence in women with previous cesarean section.

نویسندگان

  • Chanderdeep Sharma
  • Mukesh Surya
  • Anjali Soni
  • Pawan Kumar Soni
  • Ashok Verma
  • Suresh Verma
چکیده

PURPOSE To estimate the risk of uterine dehiscence/rupture in women with previous cesarean section (CS) by comparing the thickness of lower uterine segment (LUS) and myometrium with trans-abdominal (TAS) and trans-vaginal sonography (TVS). METHOD In this case-control study, in 100 pregnant women posted for elective CS (with or without previous CS; group 1 and group 2 respectively), the thickness of LUS and myometrium was measured sonographically (TAS and TVS). Intra-operatively, LUS was graded (grades I-IV), and its thickness was measured with calipers. The primary outcome of the study was correlation between echographic measurements (TAS and TVS) and features of LUS (grades I-IV) at the time of CS. Secondary outcomes were correlation between myometrial thickness, number of previous CS, and inter-delivery interval with LUS (grades I-IV). RESULTS Sonographic measurements of LUS and myometrium were significantly different between the two groups (both TAS and TVS p value = 0.000 each). However, the number of previous CS (p = 0.440) and inter-delivery interval (p = 0.062) had no statistically significant correlation with thickness of LUS. CONCLUSIONS Sonographic evaluation of LUS scar and myometrial thickness (both with TAS and TVS) is a safe, reliable, and non-invasive method for predicting the risk of scar dehiscence/rupture. Specific guidelines for TOLAC, after sonographic assessment of women with previous CS, are need of the hour.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Transvaginal Ultrasonographic Measurement of Lower Uterine Segment in Term Pregnant Patients with Previous Cesarean Section

Background: With an aim to reduce the rates of repeat cesarean section in women with a previous scar, prediction of scar rupture or dehiscence is important. If we could predict the risk of rupture by measuring the scar thickness closer to term, we could pursue a trial of scar safely. Aims: To evaluate the use of ultrasound measured thickness of lower uterine segment as one of the predictors of ...

متن کامل

Evaluation of Uterine Scar on Repeat Second Cesarean Section in Patients with Previous Cesarean Section

only marginally increased among women undergoing a trial of labor2 than among those undergrant an elective repeat cesarean section (0.4% vs 0.2% OR=2.1), with a significant decrease in need for transfusion (OR=0.57) or hysterectomy (OR=0.39), has led authorities to encourage vaginal birth after cesarean3. A group of investigators concluded4 that among women with a previously scarred uterus, ind...

متن کامل

Two and Three Dimensional Ultrasound Assessment of Cesarean Section Scars in Pregnant Women with Previous One or Two Cesarean Section and Its Correlation to Intraoperative Findings

The risk of uterine scar dehiscence and uterine rupture is inversely related to the lower uterine segment (LUS) thickness as measured by ultrasound. Three dimensional ultrasound can increase the reliability of ultrasound in prediction of scar dehiscence. Transvaginal three dimensional ultrasound measurement of the muscular layer thickness of the lower uterine segment seems to be the most reliab...

متن کامل

Sonographic Lower Uterine Segment Thickness Measurement and Risk of Uterine Scar Defect in Women with Previous Caesarean Section

Background: Risk of scar defect is inversely correlated with lower uterine segment thickness. The study aims to assess the diagnostic accuracy of sonographic measurement of the lower uterine segment thickness near term in predicting uterine scar defect in women with prior Caesarean section and ascertain the best cut-off value for predicting uterine rupture in our country. Methods: This observat...

متن کامل

Measurements of the Lower Uterine Segment at Term in Women with Previous Cesarean Delivery

Purpose: To evaluate the accuracy of sonographic measurements of the lower uterine segment (LUS) thickness at term in predicting uterine scar defects in women with previous Cesarean delivery (CD). Methods: Eighty-nine pregnant women who underwent CD between 37 and 41 weeks of gestation from 2013 to 2015 were enrolled in this study and divided into two groups. Group A consisted of women with pre...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of obstetrics and gynaecology of India

دوره 65 2  شماره 

صفحات  -

تاریخ انتشار 2015